首页 | 本学科首页   官方微博 | 高级检索  
相似文献
 共查询到19条相似文献,搜索用时 187 毫秒
1.
建立同时测定兽用消毒剂枸橼酸苹果酸粉中枸橼酸和苹果酸含量的高效液相色谱方法。采用Agilent Eclipse XDB-C18(250mm×4.6mm,5μm)色谱柱,以乙腈-10mL/L磷酸溶液(2.5∶97.5,V/V)为流动相进行洗脱,流速为1.0mL/min,检测波长为210nm,柱温为35℃,进样量为20μL。枸橼酸和苹果酸色谱峰分离度良好。枸橼酸和苹果酸分别在100μg/mL~1 000μg/mL和50μg/mL~500μg/mL范围内线性关系良好。精密度、稳定性和重现性等考察结果的相对标准偏差(RSD)均小于1.0%;而平均回收率均在98%~101%之间,RSD均小于0.5%,符合方法学要求。6份供试品中枸橼酸和苹果酸的含量也均符合要求。建立的高效液相色谱法能够同时定量测定枸橼酸和苹果酸的含量,可用于枸橼酸苹果酸粉的质量控制。  相似文献   

2.
建立了普鲁卡因青霉素注射液鉴别和含量测定的HPLC方法。样品经HPLC分离后进行定性鉴别和含量测定。结果显示供试品溶液主峰的保留时间与对照品溶液主峰的保留时间一致,普鲁卡因的线性范围为0.432-0.648 mg/mL,青霉素的线性范围为0.64-0.96 mg/mL,普鲁卡因和青霉素的添加回收率分别为101.35%和100.11%。该方法结果准确度高、精密度好,可作为质量标准控制方法。  相似文献   

3.
文章建立了HPLC法测定盐酸芬戈莫德原料药含量的方法。试验结果表明:盐酸芬戈莫德在0.055 0~0.165 0 mg/ml范围内呈良好的线性关系,Y=158 490 160X-51 837.4,r~2=0.999 8;精密度RSD为0.11%,表明仪器精密度良好;重复性RSD为0.09%,表明含量测定重复性良好;稳定性RSD为0.13%,表明供试品溶液至少在12 h内稳定;加样回收率RSD为1.37%,表明此方法可行;样品耐受性良好。由以上数据显示测定结果准确、可靠,表明所建立的HPLC法能有效的控制本品的质量。  相似文献   

4.
试验旨在建立测定马香苓口服液中百秋李醇含量的研究方法。本研究采用气相色谱法,其色谱条件是使用色谱柱HP-5毛细管柱;柱温采用程序升温(初始温度150℃,保持18 min,以50℃/min速率升至280℃,保持5 min);进样口温度为280℃;载气:高纯氮气;流速1 mL/min;进样量1μL,分流比20∶1;检测器为氢火焰离子化检测器,温度为280℃;氢气流速40 mL/min,空气流速370 mL/min;分别进行系统适用性试验、专属性试验、线性范围考察、检测限和定量限的确定、精密度试验、稳定性试验、重复性试验、加样回收率试验、耐用性试验,并对10批样品进行了含量测定。结果显示,专属性溶液中的溶剂峰、药液的杂质峰与主成分峰能达到有效分离且分离度符合要求(R≥1.5),表明该方法系统适用性良好;阴性对照溶液未检出色谱峰,表明样品中其他成分不干扰测定;百秋李醇定量限和检测限分别为2.842和0.812μg/mL;百秋李醇检测质量浓度在15.86~1 015μg/mL范围内与峰面积积分值呈良好的线性关系(y=0.869x-10.45,R~2=0.999,n=7)。精密度试验、稳定性试验(日内和日间精密度)、重复性试验的平均RSD分别为0.90%、1.63%和1.83%、2.90%,其RSD均在可控范围内(RSD≤3%);平均加样回收率为95.36%,RSD=2.82%(n=6),表明所建立的气相色谱法检测百秋李醇的含量回收率良好;进行耐用性试验,最终验证所建立的色谱方法可以稳定检测百秋李醇的含量。经方法学验证,该方法准确稳定,简便可行,能够作为马香苓口服液君药广藿香中百秋李醇的含量控制方法,同时也为该制剂质量控制提供了一种有效的检测方法,暂定本品中广藿香药材按百秋李醇计不少于47.53μg/mL。  相似文献   

5.
为了建立测定泰拉霉素注射液中泰拉霉素含量的高效液相色谱方法,试验采用Waters XBridge C_(18)(150 mm×4.6 mm,5.0μm)色谱柱,以甲醇-乙腈-0.05 mol/L磷酸二氢钾溶液(pH值为7.0,45∶25∶30)为流动相进行洗脱,流速为1.0 mL/min,检测波长为205 nm,柱温为35℃,进样量为25μL。结果表明:泰拉霉素A和B色谱峰峰形良好,且均能达到完全分离;在0.05~5.00 mg/mL范围内线性关系良好(R~20.999);精密度和稳定性等考察结果的相对标准偏差(RSD)均小于2.0%;而加样回收率均在97%~104%之间,RSD均小于1.0%,均符合方法学要求。6份泰拉霉素注射液供试品中泰拉霉素A和B的相对含量符合要求,泰拉霉素的总含量也符合要求。说明试验建立的高效液相色谱法能够定量测定泰拉霉素的含量。  相似文献   

6.
为了建立当归补血颗粒的质量检测标准,采用薄层色谱法(TLC)对组方药物当归有效成分藁本内酯进行鉴别,采用高效液相色谱法(HPLC)分别对组方药当归中的阿魏酸和黄芪中的有效成分黄芪甲苷进行含量测定。结果表明,藁本内酯薄层色谱斑点清晰,分离度好,特异性强;阿魏酸浓度在0.502μg/mL~20.06μg/mL范围内与峰面积呈良好的线性关系(R~2=0.999 5),3种浓度阿魏酸对照品精密度RSD均不大于1.5%,重复性试验RSD为0.63%,稳定性试验RSD为0.93%,加样回收率平均为98.21%,色谱图中阴性对照无干扰,专属性良好。黄芪甲苷浓度在0.401μg/mL~8.016μg/mL范围内与峰面积呈良好的线性关系(R~2=0.999 2),3种浓度黄芪甲苷对照品精密度RSD均不大于1.5%,重复性试验RSD为1.76%,稳定性试验RSD为1.66%,加样回收率平均为97.68%,色谱图中阴性对照无干扰,专属性良好。说明建立的检测方法简便、准确、专属性强、重复性好,可对当归补血颗粒的质量进行有效控制。  相似文献   

7.
通过考察3种替米考星颗粒制剂在酸性溶液和缓冲液中的释放情况,为新制剂的进一步研发和临床应用提供理论依据。采用高效液相色谱法对3种不同制剂中替米考星的含量及其体外溶出度进行测定。色谱柱选择Hypersil ODS-2 C18(4.6 mm×250 mm, 5μm),以水∶乙腈∶四氢呋喃∶磷酸二丁胺(790∶130∶55∶25)为流动相,流速1.0 mL/min,检测波长290 nm,柱温30℃。分别以盐酸溶液和磷酸盐缓冲液为溶出介质,测定3种新研制的替米考星不同制剂体外溶出曲线,溶出方法选用浆法,转速为75 r/min,温度为37℃±0.5℃。在所建立的方法学基础上,替米考星在10μg/mL~1000μg/mL范围内与峰面积呈良好的线性关系,在90 min时3种新研制的替米考星不同制剂在酸性溶液中的溶出度分别为100%、5.73%和8.29%,供试品1与供试品2、供试品3及对照品之间差异显著(P<0.05),供试品2、供试品3与对照品之间无明显差异;120 min时3种新研制的替米考星不同制剂在磷酸盐缓冲液中的累积溶出度分别为100%、97.53%和93.60%,3种供试品与对照品...  相似文献   

8.
试验旨在建立测定马香苓口服液中百秋李醇含量的研究方法。本研究采用气相色谱法,其色谱条件是使用色谱柱HP-5毛细管柱;柱温采用程序升温(初始温度150 ℃,保持18 min,以50 ℃/min速率升至280 ℃,保持5 min);进样口温度为280 ℃;载气:高纯氮气;流速1 mL/min;进样量1 μL,分流比20:1;检测器为氢火焰离子化检测器,温度为280 ℃;氢气流速40 mL/min,空气流速370 mL/min;分别进行系统适用性试验、专属性试验、线性范围考察、检测限和定量限的确定、精密度试验、稳定性试验、重复性试验、加样回收率试验、耐用性试验,并对10批样品进行了含量测定。结果显示,专属性溶液中的溶剂峰、药液的杂质峰与主成分峰能达到有效分离且分离度符合要求(R ≥ 1.5),表明该方法系统适用性良好;阴性对照溶液未检出色谱峰,表明样品中其他成分不干扰测定;百秋李醇定量限和检测限分别为2.842和0.812 μg/mL;百秋李醇检测质量浓度在15.86~1 015 μg/mL范围内与峰面积积分值呈良好的线性关系(y=0.869x-10.45,R2=0.999,n=7)。精密度试验、稳定性试验(日内和日间精密度)、重复性试验的平均RSD分别为0.90%、1.63%和1.83%、2.90%,其RSD均在可控范围内(RSD ≤ 3%);平均加样回收率为95.36%,RSD=2.82%(n=6),表明所建立的气相色谱法检测百秋李醇的含量回收率良好;进行耐用性试验,最终验证所建立的色谱方法可以稳定检测百秋李醇的含量。经方法学验证,该方法准确稳定,简便可行,能够作为马香苓口服液君药广藿香中百秋李醇的含量控制方法,同时也为该制剂质量控制提供了一种有效的检测方法,暂定本品中广藿香药材按百秋李醇计不少于47.53 μg/mL。  相似文献   

9.
改进和完善苍蓝口服液中盐酸小檗碱含量测定的供试品溶液制备方法。精密量取苍蓝口服液5 m L,置25 mL容量瓶中,加流动相稀释至刻度,摇匀,过滤,取续滤液作为供试品溶液。结果表明,供试品溶液制备改进后的方法简单高效、准确性高、重现性好,适用于苍蓝口服液中盐酸小檗碱含量检测。  相似文献   

10.
采用微生物管碟法和比浊法测定注射用硫酸链霉素含量,微生物管碟法是将1.2和0.6U/mL的抗生素溶液加入到牛津杯中,通过溶液的渗透与摊布在固体平板中的枯草芽孢杆菌相互作用形成抑茵圈,通过测量标准品与供试品形成的抑茵圈直径来计算供试品的含量;比浊法是在石英比色管中按拉丁方排列顺序加入7.5和5.0U/mL的抗生素溶液及含金黄色葡萄球菌的液体培养基,通过在线测定标准品与供试品吸光度来计算供试品的含量,测定数据表明:微生物管碟法与比浊法测定注射用硫酸链霉素含量结果无显著差异,同时阐述2种试验方法各自的优缺点及应注意的问题.  相似文献   

11.
The assay was aimed to determine the content of pinoresinol diglucoside (PDG) in Eucommie ulmoides immunoenhancement liquids. The chromatographic conditions were as follows:Inersustain® C18 column (250 mm×4.6 mm,5 μm) was under column temperature of 35℃, the mobile phase consisted of acetonitrile-0.2% phosphoric acid(15:85)with a flow rate of 1.0 mL/min,and the UV detection wavelength was 277 nm. Ethyl acetate was used as extraction solvent. In order to determine PDG of the test solution under the chromatographic conditions, the number of theoretical plates and resolution were used as system suitability indicators. Linear regression on reference substance (PDG),linearity range and the precision, stability, and reproducibility of the analysis method, the recovery test of adding samples were all determined. The results showed that under the content determination method, the number of theoretical plates of PDG in the test solution was 8 588, and the resolution was 3.046. PDG performed good linear relation at the linear range between 6 and 192 μg/mL, and the related coefficient was 0.9996. The precision experiments showed that the relative standard deviation (RSD) of reference substance solution was 0.74%. The RSD of reproducibility and stability of PDG in the test solution was 4.50% and 2.69%, respectively. The average recovery was 98.74% with RSD 0.65% (n=9). Under the chromatographic conditions established above, the contents of PDG in the test sample were between 0.124 and 0.127 mg/mL. The conclusion was that the RP-HPLC method performed well system suitability, precision, reoroducibility, stability, and high recovery rate. Meanwhile this method was quick, simple and reliable. It could be used to determine the content of PDG in Eucommie ulmoides immunoenhancement liquids.  相似文献   

12.
试验旨在建立一种高效液相色谱检测方法,同时测定乙酰氨基阿维菌素(EPR)缓释注射剂的主成分与有关物质,采用外标法计算主成分的含量,采用自身对照法计算有关物质的含量。色谱柱为Phenomenex Luna 5 μ-C8-100A 250 mm×4.60 mm,5 μm;色谱条件为:流动相为乙腈-0.1%高氯酸水溶液,梯度洗脱,流速为1.5 mL/min,检测波长为245 nm,柱温为35 ℃,进样量为20 μL。结果表明,EPR缓释注射剂主成分与杂质分离度良好,B1a与B1b之间分离度>3;在EPR浓度为1.5625~1 000 μg/mL的范围内线性关系良好;EPR的检测限与定量限分别为0.01和0.34 μg/mL,3种精密度的相对标准偏差(RSD)均<2%,稳定性的RSD为0.28%,加样回收率为102.54%,且RSD为3.14%(n=9)。耐用性试验表明,EPR缓释注射剂主成分的分离度均>1.5,理论塔板数>4 500,表明该检测条件的耐用性良好。3批样品中,EPR缓释注射剂含量的平均值为102.60%,B1b占B1a与B1b之和的1.68%,总杂质的平均含量为2.57%。建立的EPR缓释注射剂中主成分含量与有关物质的测定方法具有简便、专属性强、灵敏度高、结果准确等特点,可用于EPR缓释注射剂的质量控制。  相似文献   

13.
本试验采用了氢化物发生-原子荧光光谱法测定牛肉中的硒,通过消解液、预还原剂、介质酸的选择等优化了试验条件并测定其检出限、精密度、加标回收率等。结果显示本试验选用2:1的混合酸作为消解液,6 mol/L HCl作为预还原剂,体积比为10%的HCl作为介质酸。硒在0~8 μg/L的范围内呈良好的线性关系,相关系数为0.9999,检出限为0.01 ng/mL。在20、30和40 μg/L 3个添加水平下牛肉的回收率为94%~104%,相对标准偏差(RSD)为3.80%。该方法具有简便、有效等特点,对肉制品中硒的测定具有一定的参考意义。  相似文献   

14.
建立了板蓝根注射液中(R,S)-告依春含量测定的高效液相色谱方法。采用Waters XBridgeC18色谱柱(150mm×4.6mm,5μm),甲醇-0.02%磷酸溶液(7:93)为流动相,流速为1.0mL/min,检测波长245nm,柱温30℃。在1-40μg/mL浓度范围内线性关系良好(r=0.9998),系统精密度RSD为0.31%(n=6),平均回收率为98.6%(RSD=0.36%)。本方法重现性好,可用于该制剂的质量控制。  相似文献   

15.
[目的]建立HPLC法测定植物源杀螨浴剂(外用)中的氧化苦参碱含量。[方法]采用Waters XBridge C18(4.6mm×150mm,5μm)色谱柱,流动相为甲醇-0.05mol/L磷酸二氢钠(含0.5%高氯酸钠)(15∶85),流速为1.0mL/min,检测波长为220nm,进样量为10μL,柱温为30℃。[结果]氧化苦参碱质量浓度在0.020592~0.45747mg/mL(Y=5.72e+006X+1.13e+004,R^2=0.9998)与峰面积积分值呈良好的线性关系;精密度试验RSD为0.3%(n=6);重复性试验RSD为1.0%(n=6);回收率试验RSD为1.6%。[结论]该法测定氧化苦参碱含量简便、快捷,稳定性好,重复性高,可用于控制植物源杀螨浴剂(外用)的质量。  相似文献   

16.
为建立伊维菌素微乳中伊维菌素含量的高效液相色谱(HPLC)测定方法,选用Hypersil ODS2 (5 μm,4.6 mm×250 mm)色谱柱,流动相为甲醇∶乙腈∶水为35∶60∶5(V/V/V),检测波长为244 nm,柱温为30 ℃,流速为1 mL/min进行测定。结果显示,伊维菌素在该色谱条件下,系统适应性良好,在80~320 μg/mL浓度范围内线性关系良好,回归方程为:Y=22 700X+2 510,R2=0.9998,总平均回收率为101.90%±2.94%,RSD为2.88%,对中试生产的3批伊维菌素微乳进行含量测定,RSD为1.86%。表明该含量测定方法准确可靠,重现性好,可用于伊维菌素微乳中伊维菌素含量的测定,并为该新型制剂的质量标准的制定和质量评价提供依据,也为后期的临床安全应用提供可靠的参考。  相似文献   

17.
建立了高效液相色谱法(HPLC)同时测定芩黄颗粒中黄芩苷和甘草酸的含量。采用Agilent Eclipse XDB-C18(250 mm×4.6 mm,5μm)色谱柱,以乙腈-0.05%磷酸溶液为流动相,梯度洗脱,检测波长为252 nm,流速为1.0 mL/min。结果显示,黄芩苷和甘草酸的进样浓度分别在61.84~618.4、8.256~82.56μg/mL(R 2=0.9999,0.9999)范围内与峰面积呈良好线性关系;精密度、重复性和稳定性试验的RSD均小于2.0%;平均加样回收率分别为100.0%、99.2%,回收率的RSD分别为1.0%、0.6%(n=6)。本方法操作简便、准确,可用于芩黄颗粒中黄芩苷和甘草酸含量的同时测定。  相似文献   

18.
In order to establish the determination method of ivermectin (IVM) in the ivermectin microemulsion injection by high performance liquid chromatography (HPLC), Hypersil ODS2 colunm (5 μm,4.6 mm×250 mm) was used in this study. The mobile phase composed of methanol, acetonitrile and water (35:60:5,V/V/V) at a flow rate of 1 mL/min. The detection wave length was set at 244 nm and the column temperature was 30 ℃. The results showed that the HPLC system suitability of IVM was good. A good linear correlation of IVM was observed within the concentration range 80 to 320 μg/mL, and the average recovery rate was 101.90%±2.94% with RSD was 2.88%, the regression equation was Y=22 700X+2 510 (R2=0.9998). The RSD of IVM content in ivermectin microemulsion injection was 1.86%. The method was accurate and reliable,reproducible,easy to operate, which could be used in new type of ivermectin microemulsion injection. The method could be used as the basis of quality control and establishing a quality standard, and to provide basis for quality evaluation, also can provide reliable reference for safe veterinary clinical application in the future.  相似文献   

19.
[目的]建立高效液相色谱法(high performance liquid chromatography,HPLC)测定亚麻籽中木酚素的含量。[方法]采用液—液萃取法提取样品,以木酚素标准品进行定量,利用Agilent C18Sym 250 mm×4.6 mm色谱柱,以甲醇水溶液(甲醇∶水=4∶6)为流动相,采用紫外检测器(波长为290 nm)检测。通过加标回收和精密度试验,进行方法学验证。[结果]亚麻籽中木酚素回收率为95%~108%,精密度RSD为7.43%。不同实验室复核检测木酚素含量接近,重复性好。[结论]该方法可用于测定亚麻籽中木酚素的含量,为木酚素的工业化提纯提供了可靠的试验基础。  相似文献   

设为首页 | 免责声明 | 关于勤云 | 加入收藏