首页 | 本学科首页   官方微博 | 高级检索  
相似文献
 共查询到20条相似文献,搜索用时 31 毫秒
1.
Pancreatitis is the most frequent disease affecting the exocrine pancreas in dogs and reliable diagnostic techniques for predicting fatal complications are lacking. Contrast‐enhanced ultrasound (CEUS) improves detection of tissue perfusion as well as organ lesion vascular pattern. Objectives of this prospective case control study were to compare perfusion characteristics and enhancement patterns of the pancreas in healthy dogs and dogs with pancreatitis using CEUS. Ten healthy dogs and eight dogs with pancreatitis were selected based on physical examination, abdominal ultrasound, and blood analysis findings. A CEUS study of the pancreas was performed for each dog and two observers who were aware of clinical status used advanced ultrasound quantification software to analyze time‐intensity curves. Perfusion patterns were compared between healthy and affected dogs. In dogs with acute pancreatitis, mean pixel and peak intensity of the pancreatic parenchyma was significantly higher than that of normal dogs (P = 0.05) in between 6 and 60 s (P = <0.0001–0.046). This corresponds to a 311% increase in mean pixel intensity in dogs with acute pancreatitis compared to healthy dogs. Wash‐in rates were greater and had a consistently steeper slope to peak in dogs with pancreatitis as opposed to healthy dogs. All dogs with pancreatitis showed a decrease in pixel intensity 10–15 days after the initial examination (P = 0.011) and their times to peak values were prolonged compared to the initial exam. Findings from the current study supported the use of CEUS for diagnosing pancreatitis, pancreatic necrosis, and disease monitoring following therapy in dogs.  相似文献   

2.
Vascular alterations play important roles in many orthopedic diseases such as osteoarthritis, tendonitis, and synovitis in both human and equine athletes. Understanding these alterations could enhance diagnosis, prognosis, and treatment. Contrast‐enhanced ultrasound (CEUS) could be a valuable method for evaluation of blood flow and perfusion of these processes in the equine distal limb, however no reports were found describing feasibility or safety of the technique. The goal of this prospective, experimental study was to describe the feasibility and safety of distal limb CEUS in a sample of six horses. For each horse, CEUS of the distal limb was performed after intravenous injections of 5 and 10 ml, as well as intra‐arterial injections of 0.5 and 1 ml contrast medium. Vital parameters were monitored and CEUS images were assessed qualitatively and quantitatively for degree of contrast enhancement. None of the horses had clinically significant changes in their vital parameters after contrast medium injection. One horse had a transient increase in respiratory rate, and several horses had mild increases of systolic blood pressure of short duration after intravenous, but not after intra‐arterial injections. Intra‐arterial injection was possible in all horses and resulted in significantly improved contrast enhancement both quantitatively (P = 0.027) and qualitatively (P = 0.019). Findings from this study indicated that CEUS is a feasible and safe diagnostic test for evaluation of the equine distal limb. Future studies are needed to assess the clinical utility of this test for horses with musculoskeletal diseases.  相似文献   

3.

Background

Contrast‐enhanced ultrasound examination (CEUS) is a functional imaging technique allowing noninvasive assessment of tissue perfusion. Studies in humans show that the technique holds great potential to be used in the diagnosis of chronic kidney disease (CKD). However, data in veterinary medicine are currently lacking.

Objectives

To evaluate renal perfusion using CEUS in cats with CKD.

Animals

Fourteen client‐owned cats with CKD and 43 healthy control cats.

Methods

Prospective case‐controlled clinical trial using CEUS to evaluate renal perfusion in cats with CKD compared to healthy control cats. Time‐intensity curves were created, and perfusion parameters were calculated using off‐line software. A linear mixed model was used to examine differences between perfusion parameters of cats with CKD and healthy cats.

Results

In cats with CKD, longer time to peak and shorter mean transit times were observed for the renal cortex. In contrast, a shorter time to peak and rise time were seen for the renal medulla. The findings for the renal cortex indicate decreased blood velocity and shorter total duration of enhancement, likely caused by increased vascular resistance in CKD. Increased blood velocity in the renal medulla has not been described before and may be because of a different response to regulatory factors in cortex and medulla.

Conclusions and Clinical Importance

Contrast‐enhanced ultrasound examination was capable of detecting perfusion changes in cats with CKD. Further research is warranted to assess the diagnostic capabilities of CEUS in early stage of the disease process.  相似文献   

4.
A 12-year-old cat was presented for investigation of weight loss and inappetence. Radiography and conventional grey-scale ultrasonography showed a large mid-body splenic mass. Contrast enhanced ultrasonography of the liver demonstrated a hypoechoic left lateral lobe nodular mass during the peak and late portal-phases of liver enhancement. Histopathology of the splenic mass and hepatic nodular mass confirmed haemangiosarcoma. The use of ultrasound microbubble contrast media in the diagnosis of hepatic metastasis in the cat has not been previously reported in the cat.  相似文献   

5.
Contrast‐enhanced ultrasonography (CEUS) is increasingly available for veterinary patients, however limited studies describe the use of this method for characterizing intrathoracic mass lesions. The aim of this prospective, observational study was to describe CEUS enhancement patterns for intrathoracic mass lesions in a sample of cats and dogs. Sixty patients (36 dogs, 24 cats) were included. Standardized CEUS examinations were performed for 41 pulmonary masses (68%) and 19 mediastinal masses (32%). Final diagnosis was based on cytology and/or histopathology. Absolute time to enhancement (TTE) values were recorded for the intrathoracic mass lesions and spleen. The spleen was used as a reference parenchymal organ to calculate relative TTE (rTTE) values. Absolute TTE of the spleen and intrathoracic mass lesions differed for dogs and cats (P = 0.001). The rTTE values significantly differed between lesions of neoplastic versus non‐neoplastic origin (P = 0.004). The majority of neoplastic pulmonary masses were supplied by bronchial arteries (63%), while most nonneoplastic pulmonary masses were supplied by pulmonary arteries (78%). The sensitivity and specificity for detecting pulmonary neoplastic masses with rTTE were 63% and 78%, respectively. Enhancement patterns for mediastinal thymomas and lymphomas significantly differed (P = 0.002). Thymomas enhanced heterogeneously in a centripetal pattern (86%), whereas lymphomas typically enhanced uniformly in a centrifugal pattern (75%). Findings indicated that CEUS is a feasible method for characterizing intrathoracic mass lesions in dogs and cats, however, the diagnostic sensitivity for detecting neoplastic pulmonary masses was low.  相似文献   

6.
Extrahepatic‐congenital portosystemic shunt is a vascular anomaly that connects the portal vein to the systemic circulation and leads to a change in hepatic microvascular perfusion. However, an assessment of hepatic microvascular perfusion is limited by conventional diagnostic modalities. The aim of this prospective, exploratory study was to assess hepatic microvascular perfusion in dogs with extrahepatic‐congenital portosystemic shunt using contrast‐enhanced ultrasonography (CEUS) using perfluorobutane (Sonazoid®). A total of 17 dogs were included, eight healthy dogs and nine with extrahepatic‐congenital portosystemic shunt. The time‐to‐peak (TTP), rising time (RT), and rising rate (RR) in the hepatic artery, portal vein, and hepatic parenchyma, as well as the portal vein‐to‐hepatic parenchyma transit time (ΔHP‐PV) measured from time‐intensity curve on CEUS were compared between healthy and extrahepatic‐congenital portosystemic shunt dogs. The RT of the hepatic artery in extrahepatic‐congenital portosystemic shunt dogs was significantly earlier than in healthy dogs (P = 0.0153). The TTP and RT of the hepatic parenchyma were significantly earlier in extrahepatic‐congenital portosystemic shunt dogs than in healthy dogs (P = 0.0018 and P = 0.0024, respectively). ΔHP–PV was significantly shorter in extrahepatic‐congenital portosystemic shunt dogs than in healthy dogs (P = 0.0018). CEUS effectively revealed changes in hepatic microvascular perfusion including hepatic artery, portal vein, and hepatic parenchyma simultaneously in extrahepatic‐congenital portosystemic shunt dogs. Rapid hepatic artery and hepatic parenchyma enhancements may reflect a compensatory increase in hepatic artery blood flow (arterialization) caused by a decrease in portal vein blood flow and may be used as an additional diagnostic test to distinguish extrahepatic‐congenital portosystemic shunt dogs from healthy dogs.  相似文献   

7.
Sentinel lymph node (SLN) mapping is a valuable and crucial diagnostic procedure in staging malignancies. We compared two non‐invasive techniques, near‐infrared (NIR) fluorescence imaging and contrast‐enhanced ultrasound (CEUS), to identify the SLNs in three superficial anatomical regions in an animal model. Six healthy laboratory dogs were included in a proof‐of‐concept trial. A NIR fluorescent dye (Indocyanine Green) and microbubbles (Sonovue) were consecutively injected subdermally in the Inguinal, axillary and popliteal region to map the SLNs. Transcutaneous NIR fluorescence imaging identified SLNs in 17 out of a total of 18 occasions. CEUS identified SLNs in all regions (18/18). Whereas NIR fluorescence imaging performed better in the visualization of the afferent lymphatic tract, CEUS demonstrated different filling patterns of the SLNs, a feature potentially critical for the concept of SLN mapping in cancer patients. Both NIR fluorescence imaging and CEUS are safe, non‐invasive, practical and accurate methods to perform real‐time transcutaneous SLN mapping with potential in a clinical setting.  相似文献   

8.
A 5‐year‐old male Norwegian Forest cat presented with increased hepatic serum biochemical parameters. Abdominal radiography showed an oval cranioventral mass and ultrasound revealed a mobile mass attached to one hepatic lobe. Computed tomography (CT) confirmed that the mass was attached to the right medial liver lobe. Differential diagnoses were an accessory liver lobe, benign neoplasia, and focal nodular hyperplasia. The mass was removed and histopathology confirmed the mass to be normal liver tissue. Accessory liver lobe should be included in the differential diagnosis of a mobile cranial abdominal mass with a similar ultrasonographic or CT appearance to the liver.  相似文献   

9.
Four dogs with an accessory spleen are described. The accessory spleens appeared as a round‐to‐triangular structure located in the perisplenic area. They were homogeneous and isoechoic with the adjacent spleen. Contrast‐enhanced ultrasound was performed using a second generation microbubble contrast medium (sulfur hexafluoride). The type and timing of enhancement of the accessory spleen was similar to that of the parent spleen. Contrast‐enhanced ultrasound is a noninvasive modality useful in distinguishing an accessory spleen from a mass of another origin.  相似文献   

10.
Gall‐bladder diseases are common in dogs and two‐dimensional ultrasonography is a current standard method for diagnosis and treatment planning. However, findings from this modality can be nonspecific. The aim of this retrospective, case series study was to describe conventional and contrast‐enhanced ultrasound (using SonoVue®) findings in a group of dogs with histologically confirmed gall bladder disease. A total of 65 dogs were included. Branchlike, heterogeneous, and homogeneous contrast enhancement of echogenic intraluminal mass‐forming lesions was a contrast‐enhanced ultrasound characteristic of polypoid lesions due to cystic mucosal hyperplasia of the gallbladder and/or tumor, which had different wash‐in and washout characteristics. In dogs with mobile or immobile biliary sludge or mucocele, the echogenic intraluminal masses remained unenhanced. A double rim mark or enhancement defect in the gallbladder wall was a characteristic of edema or necrosis/rupture of the wall, respectively. Conventional ultrasonography correctly identified biliary sludge or mucocele in 36/37 dogs, cholecystitis/edema in 44/47 dogs, necrosis/rupture in 19/25 dogs, and gallbladder neoplasia in three of three dogs with these pathologies. It falsely identified biliary sludge or mucocele in eight of 28 dogs, cholecystitis/edema in three of 15 dogs, necrosis/rupture in 13/37 dogs, and gall‐bladder neoplasia in 20/59 dogs that did not have these pathologies. Contrast‐enhanced ultrasound correctly identified cholecystitis/edema in 42/47 dogs, but falsely identified cholecystitis/edema in three of 18 dogs. It correctly identified necrosis/rupture, benign polypoid lesions, and gallbladder neoplasia in all dogs with no false‐positive results. Findings supported contrast‐enhanced ultrasound as a complement to conventional ultrasonography for dogs with suspected gallbladder pathologies such as edema, necrosis, and rupture.  相似文献   

11.
This prospective case study aimed to clarify the clinical significance of contrast-enhanced ultrasound (CEUS) for the differential diagnosis of canine adrenal tumors. Forty-three client-owned dogs with adrenal tumors were included. All dogs underwent CEUS, which was evaluated qualitatively and quantitatively. The peak signal intensity (PI), time to peak signal intensity (TPI), mean transit time (MTT), upslope, and downslope were calculated for each time-intensity curve. The histopathological diagnosis of each resected mass was compared with the CEUS findings and parameters. Enhancement distribution, vascularity, tortuous nourishing vessels, enhancement pattern, and late-phase enhancement did not differ significantly between adrenal cortical adenoma (CA), adenocarcinoma (CAC), and pheochromocytoma (PHEO) in qualitative assessment. In PHEO, the TPI was significantly more rapid compared with that in CA (P=0.0287) and CAC (P=0.0404). The MTT in PHEO was significantly shorter than that in CA (P=0.0016) and CAC (P=0.0003). Upslope in PHEO was larger than that in CAC (P=0.0406). Downslope in PHEO was significantly larger than that in CA (P=0.0048) and CAC (P=0.0018). A receiver operating characteristic curve analysis demonstrated that the area under the MTT curve yielded 0.91 for distinguishing PHEO from adrenocortical tumors in dogs; an MTT cut-off value less than 6,225 msec yielded a sensitivity of 69%, specificity of 94%, and likelihood ratio of 12.46. CEUS appears to be clinically applicable for the differential diagnosis between cortical and medullary origins of primary adrenal tumors in dogs.  相似文献   

12.
R.T. O''Brien  DVM  MS    M. Iani  DVM    J. Matheson  DVM    F. Delaney  BS    K. Young  VMD  PhD 《Veterinary radiology & ultrasound》2004,45(6):547-553
Thirty-two dogs with spontaneous hepatic nodules were given intravenous ultrasound contrast medium (Definity or Sonovue) and imaged with contrast harmonic software on a conventional ultrasound machine system. Digital video images were initially reviewed to describe the perfusion pattern of malignant nodules. The images were reviewed again to test this pattern against all individual nodules. Subjectively, there was improved conspicuity of malignant nodules after contrast enhancement compared with conventional imaging and increased numbers of malignant nodules were often noted. There was decreased conspicuity of benign nodules and no additional nodules were seen after contrast enhancement. There was a highly significant (P < 0.0001) association of malignancy with a hypoechoic nodule at surrounding normal liver peak contrast enhancement. Benign nodules were isoechoic to the surrounding normal liver at peak contrast enhancement. Only one benign nodule (hepatoma) had regions of hypoechogenicity compared with the surrounding normal liver at peak liver contrast enhancement. The sensitivity, specificity, positive predictive value, negative predictive value, and accuracy were highly significant (P < 0.0001) (100%, 94.1%, 93.8%, 100%, and 96.9%, respectively). No complications or morbidity was noted throughout the course of the study. Contrast harmonic ultrasound appears to be accurate at discriminating between naturally occurring benign and malignant nodules in the liver of dogs.  相似文献   

13.
Contrast-enhanced ultrasound using Sonazoid, a novel contrast medium with a liver-specific Kupffer phase, was evaluated in canine focal liver lesions Twenty-five dogs with a liver mass were given intravenous Sonazoid, and the enhancement pattern in the arterial, portal, and parenchymal phase was characterized. An enhancement defect in the lesion in the parenchymal phase was observed in all malignant lesions, whereas only one of nine benign lesions had a filling defect. The diagnostic value of the presence of a filling defect for malignancy was statistically significant (100% sensitivity, 88.9% specificity, 94.1% positive predictive value, 100% negative predictive value), and was equal to that of hypoenhancement in the portal or delayed phase. The defect pattern (clear or irregular defect) was dependent ( P <0.05) on the types of malignancy (i.e., hepatocellular carcinoma and other types of malignancies). In the arterial phase, five of the six hepatocellular carcinomas had hypervascularity, whereas no other lesion was characterized by hypervascularity. In some dogs, additional lesions that could not be observed with conventional B-mode ultrasonography were detected in the parenchymal phase. The enhancement pattern of Sonazoid, especially in the parenchymal phase, has potential as a diagnostic tool for canine focal liver lesions.  相似文献   

14.
Contrast‐enhanced multi‐detector computed tomography (CE‐MDCT) is used routinely in evaluating human patients with acute abdominal symptoms. Contrast‐enhanced ultrasound (CEUS) continues to be in its infancy as it relates to evaluation of the acute abdomen. The purpose of this study was to compare survey radiography, B‐mode ultrasound, CEUS, and CE‐MDCT findings in canine patients presenting with acute abdominal signs; with a focus on the ability to differentiate surgical from non‐surgical conditions. Nineteen dogs were prospectively enrolled. Inclusion required a clinical diagnosis of acute abdominal signs and confirmed surgical or non‐surgical causes for the clinical signs. Agreement for the majority of recorded imaging features was at least moderate. There was poor agreement in the identification of pneumoperitoneum and in the comparison of pancreatic lesion dimensions for B‐mode vs. CEUS. The CT feature of fat stranding was detected in cases including, but not limited to, gastric neoplasia with perforation, pancreatitis, and small intestinal foreign body. Ultrasound underestimated the size and number of specific lesions when compared with CE‐MDCT. Contrast‐enhanced ultrasound was successful in detecting bowel and pancreatic perfusion deficits that CE‐MDCT failed to identify. Accuracy for differentiation of surgical vs. non‐surgical conditions was high for all modalities; 100%, 94%, and 94% for CE‐MDCT, ultrasonography and survey radiography respectively. Findings indicated that CE‐MDCT is an accurate screening test for differentiating surgical from non‐surgical acute abdominal conditions in dogs. Focused CEUS following CE‐MDCT or B‐mode ultrasonography may be beneficial for identifying potentially significant hypoperfused lesions.  相似文献   

15.
Gall bladder necrosis and rupture are life‐threatening conditions in dogs requiring surgical intervention and early diagnosis is essential. Human patients with suspected gall bladder necrosis/rupture are commonly evaluated with contrast‐enhanced ultrasonography (CEUS), however this procedure has not been described in dogs with suspected gall bladder necrosis/rupture. In a prospective diagnostic cohort study, CEUS (using SonoVue contrast medium) was performed in 93 dogs with gallbladder lesions identified by abdominal conventional ultrasonography. Necrosis/rupture was identified by CEUS as a focal lack of enhancement of the gallbladder wall. Dogs with positive CEUS finding for necrosis/rupture (complete lack of regional wall enhancement) underwent immediate surgery as did dogs with other biliary disorders requiring surgery. Dogs with negative CEUS findings or those not requiring surgery were managed medically. In cases undergoing surgery, necrosis/rupture was confirmed intraoperatively (and via histopathology). Absence of necrosis/rupture was confirmed either intraoperatively (via histopathology) or was assumed to be absent by complete recovery with medical management. Forty‐nine dogs underwent surgery and cholecystectomy: 24 had necrosis/rupture. CEUS was more accurate (100% sensitive and specific) in diagnosing gallbladder wall necrosis/rupture than conventional ultrasonography (75% sensitive and 81% specific) (P < 0.03). In conclusion, CEUS provides accurate characterization of gallbladder wall integrity that can impact decisions regarding clinical management, either surgical or medical.  相似文献   

16.
A 9‐week‐old female Rhodesian Ridgeback presented with exophthalmos following minor blunt trauma to the left orbital area. Ocular ultrasound showed an extraconal retrobulbar mass ventromedial to the left globe. Magnetic resonance (MR) imaging demonstrated a thrombosed orbital vascular malformation without intracranial extension. Doppler ultrasound features of nonpulsatile slow flow were consistent with an orbital varix. Contrast‐enhanced dynamic time‐resolved and high‐resolution MR angiography demonstrated the varix arose from the anastomotic branch of the dorsal and ventral external ophthalmic veins. Conservative management led to a positive outcome defined as a visual eye and nearly normal cosmetic appearance at 8‐month follow‐up.  相似文献   

17.
ObjectiveTo evaluate the dexmedetomidine‐induced reduction in organ blood flow with quantitative contrast‐enhanced ultrasound (CEUS) method and to observe the influence of MK‐467 on such reduction.Study designRandomized cross‐over study.AnimalsSix adult purpose‐bred laboratory beagle dogs (mean body weight 15.3 ± 1.9 kg).MethodsContrast‐enhanced ultrasound was performed on six conscious healthy laboratory beagles. The animals on separate occasions underwent three treatments: awake without any medication (CTRL), dexmedetomidine 10 μg kg?1 (DEX) and DEX + MK‐467 500 μg kg?1 (DMK) intravenously (IV). The kidney (10–15 minutes post‐treatment), spleen (25–30 minutes post‐treatment), small intestine (40–45 minutes post‐treatment) and liver (50–55 minutes post‐treatment) were examined with CEUS. A time curve was generated and the following perfusion parameters were analysed: arrival time (AT), time to peak from injection (TTPinj), peak intensity (PI) and wash‐in rate (Wi). In addition to CEUS, renal glomerular filtration rate was indirectly estimated by the rate of iohexol elimination.ResultsAT and TTPinj were significantly higher for DEX than for CTRL in all studied organs. The same parameters were significantly higher for DEX than for DMK in the kidney, spleen and small intestine. PI was significantly lower for DEX than for CTRL or DMK in the kidney. Wi was significantly lower for DEX than for CTRL or DMK in the kidney and significantly lower than for CTRL only in the small intestine. Plasma concentration of iohexol was significantly higher after DEX than CTRL administration.ConclusionsContrast‐enhanced ultrasound was effective in detecting DEX‐induced changes in blood flow. MK‐467 attenuated these changes.Clinical relevanceClinicians should consider the effects of the sedation protocol when performing CEUS. Addition of MK‐467 might beneficially impact the haemodynamic function of sedation with alpha‐2 adrenoceptor agonists.  相似文献   

18.
A noninvasive method for quantifying adrenal gland vascular patterns could be helpful for improving detection of adrenal gland disease in dogs. The purpose of this retrospective study was to compare the contrast‐enhanced ultrasound (CEUS) characteristics of adrenal glands in 18 dogs with pituitary‐dependent hyperadrenocorticism (PDH) vs. four clinically healthy dogs. Each dog received a bolus of the contrast agent (SonoVue®, 0.03 ml/kg of body weight) into the cephalic vein, immediately followed by a 5 ml saline flush. Dynamic contrast enhancement was analyzed using time–intensity curves in two regions of interest drawn manually in the caudal part of the adrenal cortex and medulla, respectively. In healthy dogs, contrast enhancement distribution was homogeneous and exhibited increased intensity from the medulla to the cortex. In the washout phase, there was a gradual and homogeneous decrease of enhancement of the adrenal gland. For all dogs with PDH, there was rapid, chaotic, and simultaneous contrast enhancement in both the medulla and cortex. Three distinct perfusion patterns were observed. Peak perfusion intensity was approximately twice as high (P < 0.05) in dogs with PDH compared with that of healthy dogs (28.90 ± 10.36 vs. 48.47 ± 15.28, respectively). In dogs with PDH, adrenal blood flow and blood volume values were approximately two‐ to fourfold (P < 0.05) greater than those of controls. Findings from the present study support the use of CEUS as a clinical tool for characterizing canine adrenal gland disease based on changes in vascular patterns.  相似文献   

19.
The aim of this retrospective, cross‐sectional, study was to evaluate clinical findings and outcomes for different ultrasonographic patterns of hepatic emphysema in dogs and cats. Dogs and cats with an ultrasonographic diagnosis of hepatic emphysema and a known outcome, from January 2010 to January 2018, were enrolled. The following data were recorded from medical and ultrasonographic records: ultrasonographic patterns of hepatic emphysema (parenchymal, portal venous, biliary), clinical signs, laboratory findings, and outcomes (favorable, poor). A total of 33 dogs and four cats met the inclusion criteria. Among these, 23 cases were classified as hepatic portal venous gas, 10 as parenchymal emphysema, and four as biliary emphysema. Clinical diagnosis categories were as follows: infection/sepsis (9), gastro‐intestinal disease (9), iatrogenic (9), trauma (5), and liver neoplasia (5). An increase in serum liver enzymes was significantly associated with parenchymal emphysema (P = .03). Other clinical and laboratory findings were not associated with the type of hepatic emphysema. Hepatic portal venous gas was mostly transient in patients with ultrasonographic follow‐up. The overall mortality was 40.5%. A significant difference was found between mortality by portal venous gas (21.7%) and mortality by parenchymal emphysema (90%) (P = .003). In conclusion, the ultrasonographic differentiation of hepatic emphysema between hepatic portal venous gas and parenchymal emphysema may be important for the prognosis of hepatic emphysema. The presence of parenchymal emphysema may be a poor prognostic indicator, while hepatic portal venous gas may be more benign. However, ultrasound findings should be carefully evaluated in the context of clinical findings.  相似文献   

20.
Abdominal ultrasonography is one of the most common diagnostic imaging modalities used for dogs with suspected insulinoma; however, pancreatic masses are clearly identified in fewer than half of affected dogs and benign pancreatic nodules can be difficult to differentiate from malignant ones. The purpose of this prospective study was to describe contrast‐enhanced ultrasonography (CEUS) characteristics of confirmed pancreatic insulinoma in a group of dogs. Inclusion criteria were as follows: (1) repeated hypoglycemia (blood glucose levels <60 mg/dl, twice or more); (2) elevated blood insulin levels with hypoglycemia; (3) pancreatic nodules detected with conventional ultrasonography; and (4) histological confirmation of pancreatic islet cell carcinoma. Immediately following conventional ultrasonography of the entire abdomen, CEUS of the pancreatic nodule and adjacent parenchyma was performed using contrast‐specific technology pulse inversion imaging and perflubutane microbubble contrast agent. Three dogs met inclusion criteria. Pancreatic nodules in all the three dogs became more clearly demarcated after injection of the contrast agent. Each nodule showed different enhancement patterns: markedly hyperechoic for 5 s, slightly hyperechoic for 1 s, and clearly hypoechoic for over 30 s. These results were not in complete agreement with previously reported CEUS findings in human patients with insulinoma. All nodules were surgically resected and histopathologically confirmed as malignant insulinomas. Findings from the current study indicated that contrast‐enhanced ultrasound may help to increase conspicuity of pancreatic insulinomas in dogs and that enhancement characteristics may be more variable in dogs than in humans.  相似文献   

设为首页 | 免责声明 | 关于勤云 | 加入收藏

Copyright©北京勤云科技发展有限公司  京ICP备09084417号