首页 | 本学科首页   官方微博 | 高级检索  
相似文献
 共查询到20条相似文献,搜索用时 822 毫秒
1.
OBJECTIVE: To determine the characteristics of an automated canine C-reactive protein (CRP) assay and evaluate 2 human CRP assays for use in dogs. Animals-56 client-owned dogs with pyometra and 11 healthy control dogs. PROCEDURES: Samples from 11 dogs with high (> 100 mg/L) or low (< 10 mg/L) CRP concentrations (determined by use of a canine ELISA) were evaluated by use of the automated canine CRP assay. Intra- and interassay imprecision was determined (by use of those 2 plasma pools), and assay inaccuracy was assessed by use of logistic regression analysis of results obtained via ELISA and the automated canine CRP assay. Two automated human CRP assays were used to measure plasma CRP concentration in 10 dogs. RESULTS: By use of the ELISA, mean +/- SD plasma CRP concentration was 96.1 +/- 38.5 mg/L and 10.1 +/- 23.2 mg/L in dogs with pyometra and control dogs, respectively. The automated canine assay had intra-assay coefficients of variation (CVs) of 7.8% and 7.9%, respectively, and interassay CVs of 11.1% and 13.1%, respectively. Results from the automated assay were highly correlated with results obtained via ELISA. The human assay results did not exceed 0.4 mg/L in any dog. CONCLUSIONS AND CLINICAL RELEVANCE: The automated canine CRP assay had less interassay imprecision, compared with the ELISA. The 2 human CRP assays were not suitable for analysis of canine plasma samples. The automated canine CRP assay was more precise than the ELISA for serial evaluations of plasma CRP concentration in dogs.  相似文献   

2.
OBJECTIVE: To develop and validate a time-resolved immunofluorometric assay (TR-IFMA) for measurement of C-reactive protein (CRP) in canine whole blood. ANIMALS: 12 healthy dogs and 35 dogs with inflammatory processes. PROCEDURE: CRP was isolated from acute-phase serum by affinity chromatography and used as a standard for calibration. Analytic and functional limit of detection and intra-assay and interassay precision were calculated. Accuracy was evaluated by recovery assays and by comparison with results of a commercial ELISA. Correlation between CRP concentrations in whole blood and corresponding plasma fractions was tested by use of TR-IFMA. Stability of blood samples at 4 degrees C was assessed during a 1-month period, and effects of anticoagulants were evaluated. Measurements of CRP in blood samples from 12 healthy dogs were compared with those of 35 dogs with inflammatory diseases. RESULTS: Analytic and functional limits of detection were 0.53 and 3.26 microg/mL, respectively. Intra-assay and interassay coefficients of variation varied between 2.1% to 8.9% and 8.0% to 12.3%, respectively. Mean recoveries of added CRP were 104% and 114%. Measurements of CRP by use of TR-IFMA and ELISA were highly correlated (R2 = 0.97). Measurements of CRP in whole blood and in corresponding plasma fractions by use of TR-IFMA were also highly correlated (R2 = 0.97). Neither storage nor use of anticoagulants disturbed measurement of CRP concentrations in whole blood. Concentrations of CRP in whole blood of dogs with inflammation were significantly higher than in healthy dogs. CONCLUSIONS AND CLINICAL RELEVANCE: Determination of CRP concentrations in whole blood may provide a diagnostic test for inflammation in dogs.  相似文献   

3.
Background: C‐reactive protein (CRP) is a sensitive marker for inflammation in people and dogs. In people, an association between CRP concentration and atherosclerosis has been reported. Atherosclerosis is rare in dogs, but the Miniature Schnauzer breed may be at increased risk for developing this vascular disease. It is not known if CRP concentrations in Miniature Schnauzer dogs differ from those in other dog breeds. Objectives: Our objectives were to validate an automated human CRP assay for measuring CRP in dogs and compare CRP concentrations in healthy Miniature Schnauzer dogs with those in non‐Miniature Schnauzer breeds. Methods: Sera from 37 non‐Miniature Schnauzer dogs with inflammatory disease were pooled and used to validate a human CRP immunoturbidimetric assay for measuring canine CRP. Blood was collected from 20 healthy Miniature Schnauzer dogs and 41 healthy dogs of other breeds. Median serum CRP concentration of healthy Miniature Schnauzer dogs was compared with that of healthy non‐Miniature Schnauzer dogs. Results: The human CRP assay measured CRP reliably with linearity between 0 and 20 mg/L. CRP concentration for healthy Miniature Schnauzer dogs (median 4.0 mg/L, minimum–maximum 0–18.2 mg/L) was significantly higher than for the healthy non‐Miniature Schnauzer dogs (median 0.1 mg/L, minimum–maximum 0–10.7 mg/L); 17 of the 20 Miniature Schnauzer dogs had values that overlapped with those of the non‐Miniature Schnauzer dogs. Conclusions: Median CRP concentration of Miniature Schnauzer dogs was slightly higher than that of other breeds of dogs. A relationship between higher CRP concentration in Miniature Schnauzer dogs and idiopathic hyperlipidemia, pancreatitis, and possible increased risk for atherosclerosis remains to be determined.  相似文献   

4.
Background: Measurement of canine serum insulin has relied on methods developed to measure human insulin. A species‐optimized test for measurement of serum insulin in dogs is now commercially available. Objective: The purpose of this study was to validate the canine ELISA for determination of serum insulin concentration in dogs. Methods: Precision was determined by evaluating intra‐ and interassay coefficient of variation (CV), and accuracy was determined by dilution and spike recovery studies. A method comparison study with samples from 34 clinically healthy dogs and 73 dogs examined for various illnesses and disorders (“patients”) was performed using the canine ELISA and an ELISA for human insulin. Biologic relevance of the canine assay was evaluated by measuring insulin in samples collected from 8 healthy dogs after administration of glucagon. A stability study was preformed with 6 samples stored at 20°C, 4–8°C, and ?20°C. Results: For the canine ELISA, intra‐ and interassay CVs were 4.3–7.8% and 4.4–7.7%, respectively. Mean recovery after dilution was 99% and recovery after spiking with porcine insulin was 116%. The canine and human ELISAs correlated well (r2=.94 for healthy dogs, r2=.88 for patient samples). After glucagon injection serum insulin concentrations increased significantly in 8 dogs. Insulin was stable for 30 days in 6 serum samples stored at ?20°C and in most samples for 8 days at 4–8°C. Insulin was stable for <3 days at room temperature (20°C). Conclusions: The new canine serum insulin ELISA had good precision and accuracy and correlated well with the previously used assay.  相似文献   

5.
OBJECTIVE: To develop and validate an ELISA for measurement of serum canine pepsinogen A (cPG A) as a diagnostic marker of gastric disorders in dogs and to measure serum cPG A in healthy dogs after food deprivation and after feeding. SAMPLE POPULATION: Sera from 72 healthy dogs. PROCEDURE: A sandwich ELISA was developed and validated. The reference range for serum concentrations of cPG A was determined in 64 healthy dogs. Postprandial changes in serum concentrations of cPG A were evaluated in 8 healthy dogs. RESULTS: Assay sensitivity was 18 microg/L, and the maximum detectable concentration was 1,080 microg/L. The observed-to-expected ratio (O:E) for 3 serial dilutions of 3 serum samples ranged from 69.3 to 104.1%. The O:E for 3 serum samples spiked with 8 concentrations of cPG A ranged from 58.8 to 120.4%. Coefficients of variation for intra- and interassay variability of 3 serum samples ranged from 7.6 to 11.9% and from 10.1 to 13.1%, respectively. Mean +/- SD serum concentration of cPG A in healthy dogs was 63.8 +/- 31.0 microg/L and the reference range was 18 to 129 microg/L. Significant increases in serum concentrations of cPG A were observed between 1 and 7 hours after feeding. CONCLUSIONS AND CLINICAL RELEVANCE: The ELISA for measuring cPG A was sufficiently sensitive, linear, accurate, precise, and reproducible for clinical use. Serum concentrations of cPG A increase substantially after feeding, which should be taken into account when conducting clinical studies.  相似文献   

6.
Background: Serum C-reactive protein (CRP) is an acute phase marker in dogs that is useful for the diagnosis and monitoring of inflammatory disease. Rapid, reliable, and automated assays are preferable for routine evaluation of canine serum CRP concentration.
Objective: The aim of this study was to evaluate whether canine serum CRP concentration could be measured reliably using an automated turbidometric immunoassay (TIA) designed for use with human serum.
Methods: A commercially available TIA for human serum CRP (Bayer, Newbury, UK) was used to measure canine serum CRP concentration. Cross-reactivity of antigen was evaluated by the Ouchterlony procedure. Intra-and interassay imprecision was investigated by multiple measurements on canine serum samples and serum pools, respectively. Assay inaccuracy was investigated by linearity under dilution and comparison of methodologies (canine CRP ELISA, Tridelta Development Ltd, Kildare, UK). Then the assay was applied to serum samples from 14 clinically healthy dogs, 11 dogs with neoplasia, 13 with infections, 8 with endocrine or metabolic diseases, and 10 with miscellaneous diseases.
Results: Cross-reactivity between canine serum CRP and the anti-human CRP antibody was found. Intra-and interassay imprecision ranged from 5.2% to 10.8% and 3.0% to 10.2%, respectively. Serum CRP concentration was measured in a linear and proportional manner. There was no significant disagreement and there was linear correlation of the results in the comparison of methodologies, except for a slight proportional discrepancy at low CRP concentrations (<10 μg/mL). Dogs with infections had a significantly higher concentration of serum CRP than did all other dogs, and dogs with neoplasia had a significantly higher concentration of serum CRP than did clinically healthy dogs.
Conclusions: Canine serum CRP concentration can be measured reliably using the commercially available TIA designed for human CRP.  相似文献   

7.
OBJECTIVE: To evaluate a canine D-dimer point-of-care (cD-d POC) test kit for use in healthy dogs and dogs with disseminated intravascular coagulation (DIC), thromboembolic disease (TED), and hemorrhage. ANIMALS: 12 healthy dogs, 18 dogs with DIC, 23 dogs with TED (19 acute and 4 chronic), and 18 dogs with hemorrhage. PROCEDURE: The cD-d POC, canine D-dimer ELISA (cD-d ELISA), human D-dimer latex agglutination (hD-d LA), and fibrin degradation product (FDP) tests were performed on citrated plasma. RESULTS: All healthy dogs had negative cD-d POC test results and mean cD-d ELISA value of 0.2 U/mL. All dogs with DIC had positive cD-d POC test results and mean cD-d ELISA value of 44 U/mL. Dogs with acuteTED had a mean cD-d ELISA value of 34 U/mL, and 17 of 19 had positive cD-d POC test results. Mean cD-d ELISA value in dogs with hemorrhage was 14 units/mL, and 15 of 18 had positive cD-d POC test results. The cD-d ELISA values in dogs with hemorrhage were significantly higher than those of healthy dogs but lower than those of dogs with DIC and acute TED. The cD-d POC, cD-d ELISA, and hD-d LA tests were comparable in differentiating healthy dogs from dogs with DIC, acute TED, or hemorrhage and appeared to be superior to measurement of FDPs. CONCLUSIONS AND CLINICAL RELEVANCE: The cD-d POC test kit can be quickly and easily used and reliably detects dogs with DIC or acute TED. Positive results may also be seen in dogs with internal hemorrhage.  相似文献   

8.
The objective was to evaluate independently the reliability of a commercially available canine serum interleukin-10 (IL-10) enzyme-linked immunoassay (ELISA) and to investigate canine serum IL-10 concentrations in healthy dogs, in dogs with a naturally-occurring acute phase reaction and in dogs following surgical stimulus by assessing intra- and interassay imprecision, inaccuracy and detection limits. Median (and range) serum IL-10 concentrations (ng/L) in the various groups were as follows: healthy dogs (n=15), 18.9 (11.2-71.5); dogs with pyometra (n=9), 37.9 (12.4-201.8); dogs with angiostrongylosis (n=8), 20.29 (14.3-108.7) and values in dogs following surgical stimulus (n=15), 14.8 (10.7-65.8). The assay measured canine serum IL-10 reliably (intra- and interassay imprecision 4.9-8.3% and 9.9-10.9%, respectively; detection limit 10.7 ng/L with no significant inaccuracy). No significant increases in IL-10 were observed following surgical stimulus and no difference in IL-10 was observed between the diagnostic groups. IL-10 values showed a higher degree of variation in dogs with an inflammatory response, i.e. those with elevated serum C-reactive protein (CRP) concentrations, compared to healthy dogs. As anticipated, healthy dogs had low levels of both analytes, whereas dogs with an acute phase response had IL-10 levels with no clear relationship to CRP concentrations, with observed low IL-10 values even when there was a marked inflammatory response.  相似文献   

9.
Background: Although prednisone and metronidazole are commonly used to treat canine inflammatory bowel disease (IBD), no randomized‐controlled trials have been performed. Hypothesis: Combination drug therapy with prednisone and metronidazole will be more effective than prednisone alone for treatment of canine IBD. Reduction in disease severity will be accompanied by decreased canine IBD activity index (CIBDAI) scores and serum C‐reactive protein (CRP) concentrations. Animals: Fifty‐four pet dogs diagnosed with IBD of varying severity. Methods: Dogs were randomized to receive oral prednisone (1 mg/kg; n = 25) or prednisone and metronidazole (10 mg/kg; n = 29) twice daily for 21 days. Clinical (CIBDAI) scores and serum CRP were determined at diagnosis and after 21 days of drug therapy. The primary efficacy measure was remission at 21 days, defined as a 75% or greater reduction in baseline CIBDAI score. Results: Differences between treatments in the rate of remission (both exceeding 80%) or the magnitude of its change over time were not observed. CRP concentrations in prednisone‐treated dogs were increased because of many dogs having active disease. Both treatments reduced CRP in comparison with pretreatment concentrations. An interaction between CIBDAI and CRP was identified in 42 of 54 dogs (78%), whereas 8 of 54 dogs (15%) showed disagreement between these indices. Conclusions and Clinical Importance: Prednisone is as effective as combined treatment with prednisone and metronidazole for induction therapy of canine IBD. CRP may be normal or increased in dogs with IBD and may be useful in assessing the response of individual dogs to treatment along with changes in the CIBDAI.  相似文献   

10.
Pythiosis (caused by the aquatic oomycete Pythium insidiosum) is a devastating and often fatal cause of either severe transmural gastroenteritis or locally invasive subcutaneous disease in dogs living in the southeastern United States. Although early diagnosis is essential for successful treatment, tools available for this task are limited. Therefore, we developed and evaluated an enzyme-linked immunosorbent assay (ELISA) for the detection of anti-P insidiosum antibodies in canine serum. A soluble mycelial extract of P insidiosum was utilized as antigen in the ELISA, which was used to evaluate serum from 43 dogs with pythiosis, 8 dogs with lagenidiosis (another canine oomycosis), 16 dogs with nonoomycotic fungal or algal infections, 22 dogs with nonfungal gastrointestinal or skin disease, and 55 healthy dogs. Results were expressed as percent positivity (PP) relative to a strong positive control serum run on each plate. Medians and ranges for each of the 5 groups were as follows: pythiosis (81.7%, 50.6-98.5%), lagenidiosis (17.3%, 11.3-29.2%), other fungal or algal infections (8.2%, 4.7-15.4%), nonfungal gastrointestinal or skin disease (6.2%, 3.9-20.7%), and healthy dogs (6.7%, 3.0-15.2%). When using a cutoff value of 40% PP, the sensitivity and specificity of the ELISA both were 100%. In addition, ELISA values measured after successful surgical therapy in 2 dogs showed a decrease of anti-P insidiosum antibody concentrations into the normal range as early as 2 months after treatment. We conclude that the ELISA is a sensitive and specific test for the diagnosis of canine pythiosis, and may be a useful tool for monitoring response to medical or surgical therapy.  相似文献   

11.
Background: There is a need for diagnostic biomarkers that can rapidly differentiate dogs with sepsis from dogs with noninfectious forms of systemic inflammatory response syndrome (NSIRS). Objectives: To compare serum NT‐pCNP concentrations among dogs with various forms of sepsis, NSIRS, and healthy controls and to evaluate the use of serum NT‐pCNP for the diagnosis of various forms of sepsis in dogs. Animals: One hundred and twelve dogs including 63 critically ill dogs (sepsis n = 29; NSIRS n = 34) and 49 healthy control dogs. Methods: Prospective clinical investigation. Serum samples were collected for NT‐pCNP measurement from dogs with sepsis or NSIRS within 24 hours of intensive care unit admission or at the time of presentation for healthy dogs. Dogs with sepsis were subclassified based on the anatomic region of infection. Serum NT‐pCNP concentrations were compared among sepsis, NSIRS and healthy groups as well as among sepsis subgroups. The area under the curve (AUC), sensitivity, and specificity for identifying dogs with sepsis were determined. Results: Using a cut‐off value of 10.1 pmol/L, AUC, sensitivity, and specificity of NT‐pCNP for differentiating dogs with sepsis from dogs with NSIRS or healthy control dogs were 0.71 (95% CI, 0.58–0.85), 65.5% (45.7–82.1%), and 89.2% (80.4–94.9%), respectively. Serum NT‐pCNP had poor sensitivity for peritoneal sources of sepsis; AUC [0.92 (0.81–1.0)], sensitivity [94% (71–100%)], and specificity [89% (80–95%)] improved when these dogs were excluded. Serum NT‐pCNP concentration was not associated with survival in the sepsis group. Conclusions and Clinical Importance: Serum NT‐pCNP is a promising diagnostic biomarker for sepsis but is a poor indicator of septic peritonitis.  相似文献   

12.
Diagnosis of animal leptospirosis is still challenging. The microscopic agglutination test, is the current method for diagnosing leptospirosis. However, this technique requires specific equipment, highly trained staff and the maintenance of live cultures of several reference strains of Leptospira for use as antigens. Recently, an ELISA (enzyme-linked immunosorbent assay) employing a Leptospira fainei serovar Hurstbridge based antigen for the early diagnostic of human leptospirosis was developed. In this study we estimate the diagnostic sensitivity and specificity of this test in identifying acute canine leptospirosis. A total of 271 serum samples divided into five panels and tested by MAT as a reference test, were used to evaluate the ELISA. Comparing acutely and non-acutely infected dogs, ELISA-Hb showed 95.6% sensitivity and 93% specificity. L. fainei-based ELISA is adequate for diagnosing acute canine leptospirosis, with high sensitivity and specificity and presenting practical advantages when compared to current techniques.  相似文献   

13.
Canine visceral leishmaniasis (CVL) is caused by Leishmania donovani complex parasites including L. donovani, Leishmania infantum and Leishmania chagasi. As some studies suggest that L. chagasi and L. infantum may be very similar or even the same species, the aim of the present study was to evaluate a commercial rapid ELISA test, originally designed for L. infantum, in the diagnosis of CVL in dogs naturally infected by L. chagasi. A total of 400 serum canine samples, including 283 positive dogs for CVL from an endemic area, 86 clinically healthy dogs from a non-endemic area and 31 dogs seropositive for confounding infectious agents (Trypanosoma cruzi, Toxoplasma gondii, Neospora caninum, Babesia canis and Ehrlichia canis) were used for test validation. An overall sensitivity of 94.7% (95% CI=91.41-97.01%) and specificity of 90.6% (95% CI=83.80-95.21%) was found, with a high degree of agreement (k=0.8445) to the indirect ELISA. When confounding infectious diseases were excluded, specificity increased to 100% (95% CI=95.8-100%), with a higher degree of agreement (k=0.8928). In conclusion, the commercial kit designed for L. infantum was a highly sensitive and specific device for detection of L. chagasi infection in dogs, which indicates high immunoreactivity similarities between L. infantum and L. chagasi.  相似文献   

14.
OBJECTIVE: To purify neutrophil elastase (NE) from dog blood and develop and validate an ELISA for the measurement of canine NE (cNE) in canine serum as a marker for gastrointestinal tract inflammation. SAMPLE POPULATION: Neutrophils from 6 dogs immediately after they were euthanatized and serum from 54 healthy dogs. PROCEDURES: cNE was purified from blood by use of dextran sedimentation, repeated cycles of freezing-thawing and sonication, cation-exchange chromatography, and continuous elution electrophoresis. Antibodies against cNE were generated in rabbits, and an ELISA was developed and validated by determination of sensitivity, dilutional parallelism, spiking recovery, intra-assay variability, and interassay variability. A reference range was established by assaying serum samples from the 54 healthy dogs and by use of the lower 97.5th percentile. RESULTS: cNE was successfully purified from blood, and antibodies were successfully generated in rabbits. An ELISA was developed with a sensitivity of 1,100 mug/L. The reference range was established as < 2,239 mug/L. Ratios of observed-to-expected results for dilutional parallelism for 4 serum samples ranged from 85.4% to 123.1%. Accuracy, as determined by spiking recovery, ranged from 27.1% to 114.0%. Coefficient of variation for 4 serum samples was 14.2%, 16.0%, 16.8%, and 13.4%, respectively, for intra-assay variability and 15.4%, 15.0%, 10.5%, and 14.6%, respectively, for interassay variability. CONCLUSIONS AND CLINICAL RELEVANCE: The purification protocol used here resulted in rapid and reproducible purification of cNE with a high yield. The novel ELISA yielded linear results and was accurate and precise. Additional studies are needed to evaluate the clinical usefulness of this assay.  相似文献   

15.
A fast agglutination screening test (FAST) for the detection of anti-Leishmania antibodies in serum samples from dogs with visceral leishmaniosis was developed. The test is based on the direct agglutination test (DAT), but combines a higher parasite concentration with a smaller test volume. In contrast to the DAT, the FAST makes use of only one serum dilution and the results can be read within 3 h as opposed to 18-20 h for the DAT. The FAST was evaluated using serum samples of confirmed cases of the disease and healthy controls collected in the most important endemic regions of canine visceral leishmaniosis, import cases of canine leishmaniosis in a non-endemic country, from non-endemic healthy controls and from dogs with other diseases. The performance of the FAST was compared with standard DAT. In the present study, the FAST had a sensitivity of 93.6% and a specificity of 89.0%. The DAT had a sensitivity of 88.6% and a specificity of 96.7%. Furthermore, using a large panel of serum samples of previously examined DAT positive or negative dogs it was shown that degree of agreement between the two tests was high (95.7%; kappa value = 0.91). The FAST offers the advantages of the DAT based on freeze-dried antigen with respect to stability of the antigen, sensitivity and specificity. Moreover, the FAST allows the rapid screening of a large number of samples, which makes the test very useful for epidemiological screening of large populations of dogs.  相似文献   

16.
Canine scabies is a challenging disease to diagnose because sarcoptic mites are hard to find on skin scrapings. The purpose of this study was to evaluate a serologic enzyme-linked immunosorbent assay (ELISA) as an aid in the diagnosis of canine scabies. In addition, serum samples were obtained post treatment to determine the duration and persistence of circulating scabies antibodies after resolution of natural infection. Nineteen dogs diagnosed with sarcoptic mange and 38 control dogs were tested. Sixteen scabies-infested dogs showed positive pretreatment ELISA results (84.2% sensitivity). Thirty-four control dogs showed negative ELISA results (89.5% specificity). In the 11 scabies dogs from which multiple post treatment serum samples were obtained, detectable antibodies were not present 1 month after treatment in four cases, but were present for 1-4.5 months post treatment in seven dogs. Our results suggest that this scabies ELISA test is useful in the diagnosis of canine scabies.  相似文献   

17.
A time-resolved immunofluorometric assay (TR-IFMA) was developed for the determination of haptoglobin (Hp) in canine serum. Haptoglobin was purified from canine acute phase serum by ammonium sulphate precipitation followed by gel filtration. This isolated dog Hp was used as the standard to calibrate the assay. Intra- and inter-assay coefficients of variation of the assay were, respectively, 5.7% and 16.6% at 0.51 mg/mL, 2.4% and 10.6% at 2.1 mg/mL and 10.5% and 11.9% at 32.5 mg/mL. The dilution of serum samples with high Hp concentrations resulted in linear regression equations with R2 of 0.99 and 0.97. A high correlation was found in serum Hp measurements by TR-IFMA and a commercial assay based on peroxidase activity of haemoglobin bound to haptoglobin (R2 = 0.96). The limit of detection for the TR-IFMA method was 0.002 microg/mL. The addition of fresh haemolysate to serum samples did not affect the haptoglobin concentration (P = 0.694). Statistical differences (P < 0.003) were found between healthy dogs and dogs with different pathological processes. In whole blood, Hp concentrations were much lower than in serum but closely related (R2 = 0.84) whereas saliva Hp concentrations were poorly related with serum concentrations (R2 = 0.53). However, the concentration of Hp in saliva was significantly (P < 0.039) higher in dogs with pathological processes compared to healthy dogs. The assay sensitivity was adequate to also be applied to whole blood and saliva specimens.  相似文献   

18.
This work reports the results obtained by a new enzyme-linked immunosorbent assay (ELISA) test developed for the serological diagnosis of canine leishmaniasis.The new ELISA is based on a recombinant protein obtained by joining different antigens of Leishmania infantum.Test performances have been evaluated through the screening 227 sera of dogs, infected and uninfected by L. infantum. The new ELISA test has been compared to the indirect immunofluorescent-antibody test (IFAT) as a reference assay of canine leishmaniasis, and to a commercial ELISA.Excluding from the total number of IFAT positive sera the 27 sera with IFAT titre 1:40 (considered doubtful), the recombinant ELISA showed 97.0% specificity, 93.9% sensitivity and 95.5% agreement with IFAT. The commercial ELISA showed 78.2% specificity, 94.9% sensitivity and 86.5% agreement with IFAT.The results demonstrate a higher performance of the new recombinant ELISA test for the detection of negative samples, with a greater agreement with the reference test (IFAT).  相似文献   

19.
OBJECTIVE: To compare serum total thyroxine (T4) concentrations obtained with an in-house ELISA and a validated radioimmunoassay (RIA). DESIGN: Laboratory trial. SAMPLE POPULATION: 50 canine and 50 feline serum samples submitted for measurement of total T4 concentration with the RIA; samples were selected to represent a wide range of concentrations (< 6 to 167 nmol/L). PROCEDURE: Results of the ELISA and RIA were compared by calculating correlation coefficients, examining linearity, determining bias and precision, and evaluating clinical interpretations. RESULTS: Correlation coefficients for results of the 2 methods were 0.84 for the canine samples and 0.59 for the feline samples. Examination of bias plots revealed large variations in ELISA results, compared with RIA results. For the feline samples, the ELISA consistently overestimated total T4 concentration obtained with the RIA. When results of the 2 methods were categorized (low, borderline low, normal, borderline high, or high), results were discordant for 24 (48%) and 29 (58%) of the canine samples and for 18 (36%) and 28 (56%) of the feline samples (depending on whether borderline high ELISA results were considered normal or high). Reliance on results of the ELISA would have led to inappropriate clinical decisions for 31 (62%) canine samples and 25 (50%) feline samples. The ELISA coefficients of variation for the pooled canine and feline samples were 18 and 28%, respectively. CONCLUSIONS AND CLINICAL RELEVANCE: Substantial discrepancies between ELISA and RIA results for T4 concentrations were detected. Thus, we concluded that the in-house ELISA kit was not accurate for determining serum total T4 concentrations in dogs and cats.  相似文献   

20.
OBJECTIVE: To identify biomarker proteins for B-cell lymphoma in canine serum by use of surface-enhanced laser desorption-ionization time-of-flight (SELDI-TOF) mass spectrometry and build classification trees with multiple biomarkers that have high sensitivity and specificity for that tumor type. SAMPLE POPULATION: Sera from 29 dogs with B-cell lymphoma and 87 control dogs (approx equal numbers of healthy dogs, dogs with malignant cancers other than B-cell lymphoma, and dogs with various nonneoplastic diseases or conditions). PROCEDURES: Serum samples were fractionated chromatographically and analyzed via SELDI-TOF mass spectrometry. Peak amplitudes of the spectra from the 2 sample groups were compared to identify potential biomarker peaks, and classification trees were built by use of computer software to detect patterns formed by multiple biomarkers among SELDI data sets. RESULTS: Several biomarker protein peaks in canine serum were identified, and a classification tree was built on the basis of 3 biomarker protein peaks. With 10-fold cross-validation of the sample set, the best individual serum biomarker peak had 75% sensitivity and 86% specificity and the classification tree had 97% sensitivity and 91% specificity for the classification of B-cell lymphoma. CONCLUSIONS AND CLINICAL RELEVANCE: On the basis of biomarker proteins identified in canine serum, classification trees were constructed, which may be useful for the development of a diagnostic test for B-cell lymphoma in dogs. Further investigation is needed to determine whether these biomarkers are useful for screening susceptible dog populations or for monitoring disease status during treatment and remission of B-cell lymphoma in dogs.  相似文献   

设为首页 | 免责声明 | 关于勤云 | 加入收藏

Copyright©北京勤云科技发展有限公司  京ICP备09084417号