首页 | 本学科首页   官方微博 | 高级检索  
     检索      


Automatic blood sampling in dairy cows
Authors:Anders Fnss  Lene Munksgaard
Institution:aDanish Institute of Agricultural Sciences, Research Centre Foulum, Department of Animal Health, Welfare and Nutrition, Blichers Allé 20, P.O. Box 50, DK-8830 Tjele, Denmark
Abstract:Loose housing systems for dairy cows are becoming increasingly common, raising new questions in the area of animal health and welfare. Some of these questions can be addressed by studying the variation in blood parameters, such as glucocortistioids. However, the traditional manual blood sampling procedure can in itself affect the responses of the animal. To address this issue we have developed a device for automated collection of multiple blood samples. The device is placed on the back of the animal and allows the animal to be kept in all types of environments, either alone or in social groups. The animal can move freely: no restraints and no handling of the animal are necessary during blood sampling.Three experiments were conducted to study the performance of the system and how the blood sampling procedure affected the cortisol responses in dairy cows. In the first experiment the accuracy of sample size and timing were investigated.In the second experiment, automatic samples were collected from six cows kept in tie-stalls, with samples taken at 3-min intervals for 38 min. At 12, 24, 36 and 38 min, a manual sample was taken by vein puncture. None of the cows showed a consistently increased cortisol response to automatic sampling, while two cows showed increased cortisol concentration after vein puncture.In the third experiment automatic blood sampling was conducted with 12 cows kept in a loose housing system. In the morning, over a period of 1.5 h, 14 blood samples were taken at varying time intervals from each cow. In the afternoon, over a period of 2.5 h, a further 14 samples were taken. Cortisol concentrations in the blood samples suggest that the cows were not affected by the blood sampling procedure.On some occasions during these experiments, it was not possible to get a sample. For the manual vein puncture 3 out of 24 samples (12.5%) were not successfully taken within a time limit of 2 min. During the automatic blood sampling process, the catheter occasionally became twisted and blocked by the movement of the cow's head. This occurred in 8 out of 84 samples (9.5%). In four of the manual samples, considerable hemolysis had occurred during the sampling procedure. No hemolysis was observed in the automatic blood samples.Automated blood sampling offers the opportunity to collect a series of samples without disturbing the animal. Data suggest that automatic blood sampling is a superior alternative to manual blood sampling, even in a tie barn.
Keywords:Blood  Sampling  Dairy cows  Stress  IceSampler
本文献已被 ScienceDirect 等数据库收录!
设为首页 | 免责声明 | 关于勤云 | 加入收藏

Copyright©北京勤云科技发展有限公司  京ICP备09084417号