aInstitute of Hydrobiology, Chinese Academy of Sciences, Wuhan 430072, PR China
bDepartment of Fisheries and Allied Aquacultures, Auburn University, AL 36849, USA
Abstract:
A direct method for measuring the 5-day biochemical oxygen demand (BOD5) of aquaculture samples that does not require sample dilution or bacterial and nutrient enrichment was evaluated. The regression coefficient (R2) between the direct method and the standard method for the analyses of 32 samples from catfish ponds was 0.996. The slope of the regression line did not differ from 1.0 or the Y-intercept from 0.0 at P = 0.05. Thus, there was almost perfect agreement between the two methods. The control limits (three standard deviations of the mean) for a standard solution containing 15 mg/L each of glutamic acid and glucose were 17.4 and 20.4 mg/L. The precision of the two methods, based on eight replicate analyses of four pond water samples did not differ at P = 0.05.