首页 | 本学科首页   官方微博 | 高级检索  
     


Comparison of capsular opacification and refractive status after placement of three different intraocular lens implants following phacoemulsification and aspiration of cataracts in dogs
Authors:Barrett W. Gift,Robert V. English,Brad Nadelstein&dagger  ,Anne K. Weigt&Dagger  , Brian C. Gilger§  
Affiliation:Animal Eye Care Associates, Cary, North Carolina;;Animal Eye Care Associates, Chesapeake, Virginia;;Animal Eye Care Associates, Laurel, Maryland;and;Department of Clinical Sciences, College of Veterinary Medicine, North Carolina State University, Raleigh, North Carolina
Abstract:Objective  To evaluate the effect of lens design and biomaterial on formation of posterior capsular opacification (PCO) and refractive correction.
Animals studied  Sixty dogs undergoing bilateral phacoemulsification for mature or diabetic cataracts.
Procedures  One randomly selected eye received a rounded edge 41D polymethyl-methacrylate (PMMA) intraocular replacement lens (IOL) and the contralateral eye received either a squared edge 41D hydrophilic acrylic IOL ( n  = 35) or a squared edge 40D hydrophobic acrylic IOL ( n  = 25). At the (mean = 79 day) reexamination period, PCO was graded using direct slit-lamp observation and by masked observer evaluation of digital images of the IOLs. Streak retinoscopy and B-mode ultrasound were performed at this period.
Results  The PCO score via direct slit-lamp was significantly lower for the hydrophilic acrylic IOL when compared to the PMMA IOL. Masked observer evaluation of digital images revealed that the acrylic IOLs had lower but generally not statistically significant PCO scores than the PMMA IOLs. Streak retinoscopy showed that the PMMA IOL was significantly closer to emmetropia (+0.44 D) when compared to either the hydrophilic acrylic (+0.96 D) or the hydrophobic acrylic (+1.2 D) IOLs. B-mode ultrasonography revealed the center of the hydrophilic acrylic IOL is 0.31 mm closer to the retina and the center of the hydrophobic acrylic IOL is 0.63 mm further from the retina when compared to the center of the PMMA to retina distance.
Conclusions  Square edged foldable acrylic IOLs show a predisposition towards generating slightly less PCO than round edged PMMA IOLs in the early postoperative period, however, both acrylic IOLs had greater persistent hyperopia than the PMMA IOLs.
Keywords:design    dog    intraocular lens    material    posterior capsular opacification    refractive error
设为首页 | 免责声明 | 关于勤云 | 加入收藏

Copyright©北京勤云科技发展有限公司  京ICP备09084417号