Disposable sensor for measurement of vitamin B(2) in nutritional premix, cereal, and milk powder |
| |
Authors: | Kadara Rashid O Haggett Barry G D Birch Brian J |
| |
Affiliation: | Luton Institute of Research in the Applied Natural Sciences, University of Luton, The Spires, 2 Adelaide Street, Luton LU1 5DU, United Kingdom. rashid.kadara@luton.ac.uk |
| |
Abstract: | Methodologies for the determination of vitamin B(2) in food matrixes and a premix using simple sample conditioning steps coupled with a convenient and cheap electrochemical sensing device are presented. Electrochemical analysis based on differential pulse voltammetry (DPV) coupled to carbon electrodes gave a well-defined reduction peak at -0.42 V versus a Ag/AgCl quasi-reference electrode. Using a straightforward sample preparation step, vitamin B(2) can be measured successfully in a nutritional premix and food products. Standard additions of riboflavin were used to confirm the analyte concentrations and to provide precision data. |
| |