首页 | 本学科首页   官方微博 | 高级检索  
     检索      

不同检测时间对原料乳中嗜冷菌检测结果的影响
引用本文:张鹏博,李智星,魏勇,张逸雪,刘文楷,蒋松.不同检测时间对原料乳中嗜冷菌检测结果的影响[J].中国乳业,2023,0(1):77-80.
作者姓名:张鹏博  李智星  魏勇  张逸雪  刘文楷  蒋松
作者单位:1 石河子大学动物科技学院,新疆石河子 832000;2 新疆天润乳业股份有限公司,新疆乌鲁木齐 832063
基金项目:兵团科技项目-奶牛场试验室健康养殖检测技术体系创新团队(2022CB014-01); 兵团十二师科技项目-优质生鲜乳安全生产关键技术集成与应用(SR2020001); 兵团十二师科技项目-万头规模化奶牛养殖全产业链提质增效技术集成与示范(SR202101)
摘    要:目的]为提高原料乳中嗜冷菌检测的准确性,制定更加合理的嗜冷菌检测标准流程。方法]本试验根据《NY/T 1331—2007乳与乳制品中嗜冷菌、需氧芽孢及嗜热需氧芽孢数的测定》中的MPC中平板计数法对新疆地区10个不同养殖模式牧场,共计120份原料乳样品在不同检测时间下的嗜冷菌水平进行检测。结果]在10-2和10-3两个稀释梯度下,3个不同模式牧场嗜冷菌检测结果均随着检测间隔时间的增加而增加,其中现代化牧场和传统牧场嗜冷菌即时检测结果与间隔12 h和24 h的检测结果均存在显著性差异(P<0.05),养殖小区嗜冷菌即时检测和间隔24 h差异显著(P<0.05),间隔12 h检测结果与即时检测和间隔24 h检测结果无显著差异(P>0.05)。结论]检测间隔时间对原料乳中嗜冷菌检测结果存在影响,样品检测间隔时间越久,最终检测结果越大,导致最终结果不具有准确性和说服性。

关 键 词:嗜冷菌  检测时间  原料乳

Effect of Different Detection Time on the Detection Results of Psychrophilein Raw Milk
ZHANG Pengbo,LI Zhixing,WEI Yong,ZHANG Yixue,LIU Wenkai,JIANG Song.Effect of Different Detection Time on the Detection Results of Psychrophilein Raw Milk[J].China Dairy,2023,0(1):77-80.
Authors:ZHANG Pengbo  LI Zhixing  WEI Yong  ZHANG Yixue  LIU Wenkai  JIANG Song
Institution:1College of Animal Science and Technology,Shihezi University,Shiihezi Xinjiang 832000;2Xinjiang Tianrun Dairy Co.,Ltd.,Urumuqi Xinjiang 832063
Abstract:Objective]In order to improve the accuracy of the detection of psychrophile bacteria in raw milk,a more reasonable standard process for the detection of psychrophile bacteria was developed.Method]In this experiment,according to the MPC in NY/T 1331-2007 Determination of the Number of psychrophile Bacteria,Aerobic Spores and Thermophilic Aerobic Spores in Milk and Dairy Products,the level of psychrophile bacteria in a total of 120 raw milk samples from ten pastures with different cultivation modes in Xinjiang were detected at different detection times. Result] Under the two dilution gradients of 10-2 and 10-3,the results of psychrophile bacteria in the three pastures of different modes increased with the increase of the detection interval,and there were significant differences between the results of psychrophile bacteria in the modern pastures and traditional large-scale pastures and the detection results of psychrophile bacteria in the 12 h and 24 h intervals(P<0.05). There were significant differences between the immediate detection and 24 h interval of psychrophile bacteria(P<0.05),but there was no significant difference between the detection results of 12 h interval and immediate detection and 24 h interval(P>0.05).Conclusion]The research results showed that the detection interval had an impact on the detection results of psychrophile bacteria in raw milk. The longer the detection interval,the larger the final detection results,resulting in the final results were not accurate and persuasive.
Keywords:psychrophile  detection time  raw milk  
点击此处可从《中国乳业》浏览原始摘要信息
点击此处可从《中国乳业》下载免费的PDF全文
设为首页 | 免责声明 | 关于勤云 | 加入收藏

Copyright©北京勤云科技发展有限公司  京ICP备09084417号