Abstract:ABSTRACT

The estimation of the pixel-wise distribution of the moisture content (MC) in wood using X-ray computed tomography (CT) requires two scans of the same wood specimen at different MCs, one of which is known. Image-processing algorithms are needed to compensate for the anisotropic distortion that wood undergoes as it dries. An alternative technique based on dual-energy CT (DECT) to determine MC in wood has been suggested by several authors. The purpose of the present study was to evaluate the hypothesis that DECT can be used for the determination of MC in real time. A method based on the use of the quotient between the linear attenuation coefficients (μ) at different acceleration voltages (the so-called quotient method) was used. A statistical model was created to estimate the MC in solid sapwood of Scots pine, Norway spruce and brittle willow. The results show a regression model with R2?>?0.97 that can predict the MC in these species with a RMSE of prediction of 0.07, 0.04 and 0.11 (MC in decimal format) respectively and at MC levels ranging from the green to the totally dry condition. Individual measurements of MC show an uncertainty of up to ±0.4. It is concluded that under the conditions prevailing in this study, and in studies referred to in this paper, it is not possible to measure MC with DECT.
Keywords:CT-scanning  dual-energy X-ray absorptiometry  wood drying  attenuation coefficient
设为首页 | 免责声明 | 关于勤云 | 加入收藏