Fixation of a complete scapular neck fracture in a foal using two 3.5 mm locking compression plates
Authors:J. L. Kamm  G. Quinn  D. van Zwanenberg
Affiliation:1. Veterinary Associates, Auckland, New Zealand;2. Hamilton Veterinary Services, Hamilton, New Zealand;3. Kumeu Veterinary Services, Auckland, New Zealand
Abstract:This report describes the successful surgical repair of a transverse, displaced scapula fracture in a foal. A 3.5 mm locking compression plate (LCP) was used on either side of the spine of the scapula. The suprascapular nerve was apparent upon dissection as it passed directly over the fracture line and care was taken to leave it intact, although the fracture line itself caused some irritation. The foal recovered without long‐term nerve damage and is sound at 1.5 years post surgery.
Keywords:horse  scapula  foal  fracture  locking compression plate