首页 | 本学科首页   官方微博 | 高级检索  
     检索      


Determination of tetracycline and streptomycin in mixed fungicide products by capillary zone electrophoresis
Authors:Hsiao Y M  Ko J L  Lo C C
Institution:Taiwan Agricultural Chemicals and Toxic Substances Research Institute, Council of Agriculture, Number 11, Kuang Ming Road, Wufeng, Taichung Hsien, Taiwan, Republic of China.
Abstract:A method of capillary zone electrophoresis (CZE) was used to determine tetracycline and streptomycin content in commercial agriculture products. The results indicated that this method was capable of analyzing the mixed fungicide in formulated products with instrument detection limit (IDL) of 0.50 microg/mL and a method detection limit (MDL) of 0.52 microg/mL for tetracycline, and IDL of 1.00 microg/mL and MDL of 1.22 microg/mL for streptomycin. Precision expressed by relative standard deviation (RSD) ranged from 1.44 to 4.37% of tetracycline and 1.00 to 4.20% of streptomycin. Recoveries were in the region of 98.2-102.5% for tetracycline and 95.3--103.0% for streptomycin. The low detection limit, the low RSD values, and the high percentage of recovery confirmed that the CZE technique is a sensitive and selective method. And the CZE method can analyze both tetracycline and streptomycin at the same time without complicated extraction and further derivative reaction.
Keywords:
本文献已被 PubMed 等数据库收录!
设为首页 | 免责声明 | 关于勤云 | 加入收藏