In vitro biomechanical comparison of dynamic compression plates with a rough contact surface and a polished contact surface for fixation of osteotomized equine third metacarpal bones |
| |
Authors: | Sod Gary A Riggs Laura M Mitchell Colin F Martin George S Gill Marjorie S |
| |
Affiliation: | Equine Health Studies Program, Department of Veterinary Clinical Sciences, School of Veterinary Medicine, Louisiana State University, Baton Rouge, LA 70803, USA. gsod@vetmed.lsu.edu |
| |
Abstract: | Objectives: To compare the number of cycles to failure of 4.5 mm broad dynamic compression plates (DCP), 4.5 mm broad limited‐contact dynamic compression plates (4.5‐LC‐DCP), and 5.5 mm broad limited‐contact dynamic compression plates (5.5‐LC‐DCP) having a rough (denoted by a prefix R‐) versus a standard smooth contact surface for the fixation of osteotomized equine 3rd metacarpal (MC3) bones. Study Design: Experimental. Animal Population: Fifteen pairs of adult equine cadaveric MC3 bones. Methods: Fifteen pairs of equine MC3 were divided into 3 test groups (5 pairs each) for comparison of (1) R‐DCP fixation with DCP fixation, (2) R‐4.5‐LC‐DCP fixation with 4.5‐LC‐DCP fixation, and (3) R‐5.5‐LC‐DCP fixation with 5.5‐LC‐DCP fixation to repair osteotomized equine MC3 bones under palmarodorsal 4‐point bending cyclic fatigue testing. For each group an 8‐hole plate with rough contact surface was applied to the dorsal surface of one randomly selected bone from each pair and a corresponding 8‐hole plate with smooth contact surface was applied dorsally to the contralateral bone from each pair. All plates and screws were applied using standard ASIF techniques. All MC3 bones had mid‐diaphyseal osteotomies. Mean number of cycles to failure for each method were compared using a paired t‐test within each group. Significance was set at P<.05. Results: Mean cycles to failure ± standard deviation was significantly greater for the R‐DCP fixation (230,025 ± 23,129) compared with the DCP fixation (103,451 ± 14,556), for the R‐4.5‐LC‐DCP fixation (99,237 ± 14,390) compared with the 4.5‐LC‐DCP fixation (46,464 ± 6325) and for the R‐5.5‐LC‐DCP fixation (65,113 ± 7796) compared with the 5.5‐LC‐DCP fixation (34,224 ± 3835). Conclusion: For the fixation of osteotomized MC3 bones, the constructs with plates having rough contact surface were superior to the corresponding constructs with plates having standard smooth contact surfaces in resisting cyclic fatigue under palmarodorsal 4‐point bending. |
| |
Keywords: | |
本文献已被 PubMed 等数据库收录! |
|