首页 | 本学科首页   官方微博 | 高级检索  
     检索      


Determination of sulfite in foods by headspace liquid chromatography
Authors:J F Lawrence  R K Chadha
Institution:Health Protection Branch, Bureau of Chemical Safety, Ottawa, Ontario, Canada.
Abstract:Sulfite was determined in a variety of foods by liquid chromatography (LC) after the samples were mixed with a solution containing mannitol, FeSO4, and Na2HPO4, adjusted to pH 11, and left to stand for 15 min at room temperature. An aliquot of the mixture was placed in a headspace vial and mixed with 50% H3PO4. After 15 min, a portion of the headspace was removed with a syringe containing LC mobile phase without acetonitrile. The syringe was shaken and an aliquot of the solution was analyzed on an anion exchange column with a mobile phase of 0.03M methane sulfonate (pH 10.8) containing 5% acetonitrile. Sulfite was detected amperometrically (glassy carbon electrode) at +0.7 V. The method was successfully compared to the FDA-modified Monier-Williams procedure for a variety of foods. Minimum detectable levels were about 1 microgram/g, based on a 15 g sample.
Keywords:
设为首页 | 免责声明 | 关于勤云 | 加入收藏