摘    要:采用吹脱法对半焦废水进行了预处理研究,以降低其氨氮、COD含量,达到后续生化处理的条件。实验结果表明:控制温度在50℃时,调节半焦废水pH值为9.6,反应时间为1.5h,其氨氮和COD的去除率分别达到75%和26%,可满足后续生化处理的要求。

关 键 词:半焦废水  吹脱法  氨氮  COD

Study on Pretreatment of Semi—coke Wastewater by using Stripping Technology
Authors:Cui Chong  Ma Qingyuan  Zhang Wei  Shan Mingjun
Institution:(Liaoning University of Science and Technology,Anshan 114051,China)
Abstract:In this study,stripping technology is used to pretreat the semi-coke wastewater for reducing its ammonia and COD content,so as to achieve the conditions of subsequent biological treatment.The results show that:when the temperature is controlled at 50 ℃,the pH value of semi-coke wastewater isadjusted to 9.6,the reaction time is 1.5 hours,and the ammonia nitrogen and COD removal rates reach 75% and 26%,which meet the requirements of subsequent biological treatment.
Keywords:semi-coke wastewater  stripping technology  ammonia  COD