首页 | 本学科首页   官方微博 | 高级检索  
     检索      


Milk production, water consumption, and somatic cell count responses of cows subject to one to two volts of alternating current.
Authors:L H Southwick  D J Wilson  P M Sears
Institution:New York State College of Veterinary Medicine, Quality Milk Promotion Services, Cornell University, Ithaca 14850.
Abstract:A dairy farm located in central New York was visited because of complaints of electrical shock in the farmhouse shower and the milk house sink. As much as 2 volts AC of potential difference was measured between the waterline and the cow platform (cow-contact voltage). Voltage was coming from the primary neutral wire. The farm's electrical service was modified so that the farmstead could be connected or disconnected from the primary neutral wire at 2-week intervals for 12 weeks. When connected to the primary neutral wire, voltage between waterline and floor ranged between 0 and 1.8 volts, producing estimated current flow through cows of 3.6 to 4.9 mA; when disconnected from primary neutral wire, voltage between waterline and floor was less than 0.1 volt. There was no difference in mean milk production, bulk tank milk somatic cell count, or water consumption among periods when cows were exposed or unexposed to voltage. Despite statistical nonsignificance, the values for somatic cell count were lower and water consumption was higher when cows were exposed to voltage than when they were not.
Keywords:
设为首页 | 免责声明 | 关于勤云 | 加入收藏