首页 | 本学科首页   官方微博 | 高级检索  
     检索      


Desaturation times between dogs preoxygenated via face mask or flow-by technique before induction of anesthesia
Authors:Barbara Ambros  Maria Valentina Carrozzo  Teela Jones
Institution:Department of Small Animal Clinical Sciences, Western College of Veterinary Medicine, University of Saskatchewan, Saskatoon, SK, Canada
Abstract:

Objective

To compare time to desaturation after induction of anesthesia following administration of oxygen via face mask or flow-by for 3 minutes.

Study design

Randomized crossover study.

Animals

A group of six healthy adult dogs weighing 15.0 ± 3.4 kg.

Methods

Dogs were anesthetized twice separated by 14 days. Intramuscular administration of dexmedetomidine (4 μg kg?1), acepromazine (0.01 mg kg?1) and butorphanol (0.2 mg kg?1) provided sedation for percutaneous insertion of a catheter into the tracheal lumen. The tip was advanced to the thoracic inlet and position confirmed using fluoroscopy. Using a sample aspiration rate 200 mL minute?1, inspired (FIO2) and end-tidal oxygen (Fe′O2) were measured. Oxygen (100 mL kg?1 minute?1) was delivered into a circle delivery system and administered to the dog for 3 minutes via face mask or flow-by from the circle Y-piece 2.5 cm from the nares. Then, propofol was administered to induce anesthesia and apnea. A pulse oximeter (lingual probe) measured hemoglobin saturation (SpO2). At SpO2 90% (desaturation point), an endotracheal tube was inserted to allow administration of oxygen and artificial ventilation. Arterial blood and data were collected at baseline (before oxygen administration), 5 seconds after induction of anesthesia, and every 30 seconds until the desaturation point was reached. Data were analyzed using an unpaired and paired t test with (p < 0.05).

Results

FIO2, Fe′O2 and PaO2 (mean ± standard deviation) were significantly higher after mask preoxygenation 89.7 ± 5.5%, 83.0 ± 7.6% and 394 ± 112 mmHg (52.4 ± 14.9 kPa)] compared with flow-by 30.0 ± 5.4%, 22.7 ± 3.8% and 133 ± 22 mmHg (17.7 ± 2.9 kPa)], respectively. Time to desaturation was significantly longer after mask treatment compared with flow-by (187 ± 67 versus 66 ± 17 seconds).

Conclusions and clinical relevance

Mask preoxygenation provided longer time to desaturation compared with the flow-by technique tested.
Keywords:anesthetic induction  dog  face mask  flow-by  preoxygenation
本文献已被 ScienceDirect 等数据库收录!
设为首页 | 免责声明 | 关于勤云 | 加入收藏

Copyright©北京勤云科技发展有限公司  京ICP备09084417号