首页 | 本学科首页   官方微博 | 高级检索  
     

MECHANICAL ANALYSIS OF TREE SPARS IN CABLE YARDING SYSTEMS
引用本文:Zhao ChenNanjing Forestry University. MECHANICAL ANALYSIS OF TREE SPARS IN CABLE YARDING SYSTEMS[J]. 林业研究, 1993, 4(2): 103-111. DOI: 10.1007/BF02843081
作者姓名:Zhao ChenNanjing Forestry University
摘    要:Tree spars,as appropriate supports for cable yarding systems,have to beverified for the strength before any real operation.This paper gives theoretical analysisfor various cases.Tree spars without guylines are normally under heavy bending stress,which dominates the strength design.For tree spars equipped with guylines,the spardeflection follows the same way as an unguyed spar.The overload of the bending stressremains the main reason of spar failures.Several diversities of tree spars from theidealized condition are investigated for the sake of better modeling of the real situation.Analysis supports that the tree spar can generally be treated as a straight cylindricalcolumn without giving significant errors.The load can be handled as centrically applied.Design methods are provided for both guyed and unguyed tree spars,which will benefit thepractice of using tree spars as an alternative for steel spars.


Mechanical analysis of tree spars in cable yarding systems
Zhao Chen. Mechanical analysis of tree spars in cable yarding systems[J]. Journal of Forestry Research, 1993, 4(2): 103-111. DOI: 10.1007/BF02843081
Authors:Zhao Chen
Affiliation:Zhao ChenNanjing Forestry University
Abstract:Tree spars, as appropriate supports for cable yarding systems, have to be verified for the strength before any real operation. This paper gives theoretical analysis for various cases. Tree spars without guylines are normally under heavy bending stress, which dominates the strength design. For tree spars equipped with guylines, the spar deflection follows the same way as an unguyed spar. The overload of the bending stress remains the main reason of spar failures. Several diversities of tree spars from the idealized condition are investigated for the sake of better modeling of the real situation. Analysis supports that the tree spar can generally be treated as a straight cylindrical column without giving significant errors. The load can be handled as centrically applied. Design methods are provided for both guyed and unguyed tree spars, which will benefit the practice of using tree spars as an alternative for steel spars.
Keywords:Cable system   Guyline   Strength design
本文献已被 CNKI SpringerLink 等数据库收录!