首页 | 本学科首页   官方微博 | 高级检索  
     

竹地板燃烧特性的锥形量热仪分析
引用本文:黄志伟,关明杰. 竹地板燃烧特性的锥形量热仪分析[J]. 西南大学学报(自然科学版), 2017, 39(6): 187
作者姓名:黄志伟  关明杰
作者单位:1. 南京林业大学 材料科学与工程学院,南京 210037;2. 国家林业局竹材工程技术研究中心,南京 210037
基金项目:江苏省自然科学基金(BK2011822);江苏高校优势学科建设工程资助项目(PAPD)
摘    要:以锥形量热仪为研究手段,对侧拼竹地板、胶合竹地板和重竹地板的燃烧特性进行了研究.结果表明,重竹地板的点燃时间最长,相对于胶合竹地板和侧拼竹地板而言分别延长了6s和12s;重竹地板的热释放速率和有效燃烧热的第二峰值相对于胶合竹地板和侧拼竹地板而言分别延迟了4min和6min;在15min前,3种竹地板的总热释放量大小依次为胶合竹地板、侧拼竹地板、重竹地板;成炭率大小依次为重竹地板、胶合竹地板、侧拼竹地板;烟比率大小依次为侧拼竹地板、胶合竹地板、重竹地板;三者的CO浓度差别不大,重竹地板的CO_2曲线第二峰出现时间分别比胶合竹地板和侧拼竹地板延长了4min和6min;重竹地板相对于胶合竹地板和侧拼竹地板而言,更有利人们在火灾场中的逃生.

关 键 词:侧拼竹地板; 胶合竹地板; 重竹地板; 燃烧特性; 锥形量热仪;

Combustion Characteristics of Bamboo Floorings Determined by a Cone Calorimeter
HUANG Zhi-wei,GUAN Ming-jie. Combustion Characteristics of Bamboo Floorings Determined by a Cone Calorimeter[J]. Journal of southwest university (Natural science edition), 2017, 39(6): 187
Authors:HUANG Zhi-wei  GUAN Ming-jie
Abstract:The aim of this research was to analyze the combustion characteristics of flat pressed bamboo flooring, side pressed bamboo flooring and strand woven bamboo flooring commonly used for residential flooring. Experiments on the three kinds of bamboo flooring were performed using a cone calorimeter according to ISO 5660-1 specifications. The results showed that time to ignition (TTTI) of strand woven bamboo flooring was the longest, extended by 6 s and 12 s compared to side pressed bamboo flooring and flat pressed bamboo flooring, respectively. The rate of heat release (RRHR) and the second peak of effective heat of combustion (EEHC) of strand woven bamboo were deferred by 4 min and 6 min, compared to side pressed bamboo flooring and flat pressed bamboo flooring, respectively. In the first 15 min of combustion, the total heat release (TTHR), char yield and smoke ratio (SSR) of the three types of bamboo flooring were in the order of side pressed bamboo flooring > flat pressed bamboo flooring > strand woven bamboo flooring, strand woven bamboo flooring > side pressed bamboo flooring > flat pressed bamboo flooring, and flat pressed bamboo flooring > side pressed bamboo flooring > strand woven bamboo flooring, respectively. The difference in CO concentration was non-significant, and the second peak of CO2 of strand woven bamboo flooring was deferred by 4 min and 6 min, compared to side pressed bamboo flooring and flat pressed bamboo flooring, respectively. So strand woven bamboo flooring was conducive to fire escape, compared to side pressed bamboo flooring and flat pressed bamboo flooring.
Keywords: