Influence of Units and Assemble on DC Flashover Voltage of Iced Insulator Strings at High Altitude Districts
作者姓名:JIANG Xing-liang  WANG Bo  ZHANG Zhi-jin  HU Jian-lin  SUN Cai-xin
作者单位:Key Laboratory of High Voltage and Electrical New Technology of Ministry of Education, College of Electrical Engineering, Chongqing University, Chongqing 400030, China
摘    要:Based on artificial tests of iced DC XZP-210 insulator strings carried out in the artificial climate chamber, the authors analyze the effects of units and assemble on the DC flashover voltage of iced insulator strings at high altitude districts. The test results show that the relationship between the DC icing flashover voltage and the insulator units is seemly linear with the increase of altitude or pollution level, although the linear relation is not obvious at the low altitude or pollution level. There is influence of the assembled form on icing flashover voltages, the flashover voltage of the horizontal string of iced insulators is highest while that of the vertical string is lowest. For various assembled forms, the effects of the air pressure on the flashover voltage of the horizontal string are most obvious.

关 键 词:iced  insulator    DC      high  altitude    string  length      flashover  voltage    assembled  form
修稿时间:3/8/2007 12:00:00 AM

Influence of Units and Assemble on DC Flashover Voltage of Iced Insulator Strings at High Altitude Districts
JIANG Xing-liang,WANG Bo,ZHANG Zhi-jin,HU Jian-lin,SUN Cai-xin.Influence of Units and Assemble on DC Flashover Voltage of Iced Insulator Strings at High Altitude Districts[J].Storage & Process,2007(7):37-41.
Authors:JIANG Xing-liang  WANG Bo  ZHANG Zhi-jin  HU Jian-lin  SUN Cai-xin
Institution:Key Laboratory of High Voltage and Electrical New Technology of Ministry of Education, College of Electrical Engineering, Chongqing University, Chongqing 400030, China
Abstract:Based on artificial tests of iced DC XZP-210 insulator strings carried out in the artificial climate chamber, the authors analyze the effects of units and assemble on the DC flashover voltage of iced insulator strings at high altitude districts. The test results show that the relationship between the DC icing flashover voltage and the insulator units is seemly linear with the increase of altitude or pollution level, although the linear relation is not obvious at the low altitude or pollution level. There is influence of the assembled form on icing flashover voltages, the flashover voltage of the horizontal string of iced insulators is highest while that of the vertical string is lowest. For various assembled forms, the effects of the air pressure on the flashover voltage of the horizontal string are most obvious.
Keywords:iced insulator  DC  high altitude  string length  flashover voltage  assembled form
点击此处可从《保鲜与加工》浏览原始摘要信息
点击此处可从《保鲜与加工》下载免费的PDF全文
设为首页 | 免责声明 | 关于勤云 | 加入收藏

Copyright©北京勤云科技发展有限公司  京ICP备09084417号