首页 | 本学科首页   官方微博 | 高级检索  
     

Analysis on the Lightning Protection Performance of 500 kV Double-circuit Transmission Line
引用本文:ZHANG Zhi-jin,LIAO Rui-jin,SUN Cai-xin. Analysis on the Lightning Protection Performance of 500 kV Double-circuit Transmission Line[J]. 保鲜与加工, 2003, 0(7): 70-73
作者姓名:ZHANG Zhi-jin  LIAO Rui-jin  SUN Cai-xin
摘    要:Using double-circuit transmission line is the developing tide for main 500 kV configuration to reduce line holding ground, so analyzing it's lightning protection performance is important to extend double-circuit transmission line in ultra high voltage network. The lightning protection performance of 500 kV double-circuit transmission line is studied with EMTP and EGM. The statistical method is applied to analyzing the lightning protection performance of back stroke by considering the randomness of working voltage's phase when lightning stroked the top tower. The result is that the line lightning protection level is different when the working voltage of conductor is different. It also improved the EGM by considering the effect of wind speed when analyzing the lightning protection performance of shielding failure. Furthermore, the results are given that wind speed has effects on the protection angle and the rate of shielding failure by using the program to calculate it.

关 键 词:double circuit  transmission line  lightning protection performance
修稿时间:2003-03-11

Analysis on the Lightning Protection Performance of 500 kV Double-circuit Transmission Line
ZHANG Zhi-jin,LIAO Rui-jin,SUN Cai-xin. Analysis on the Lightning Protection Performance of 500 kV Double-circuit Transmission Line[J]. Storage & Process, 2003, 0(7): 70-73
Authors:ZHANG Zhi-jin  LIAO Rui-jin  SUN Cai-xin
Abstract:Using double-circuit transmission line is the developing tide for main 500 kV configuration to reduce line holding ground, so analyzing it's lightning protection performance is important to extend double-circuit transmission line in ultra high voltage network. The lightning protection performance of 500 kV double-circuit transmission line is studied with EMTP and EGM. The statistical method is applied to analyzing the lightning protection performance of back stroke by considering the randomness of working voltage's phase when lightning stroked the top tower. The result is that the line lightning protection level is different when the working voltage of conductor is different. It also improved the EGM by considering the effect of wind speed when analyzing the lightning protection performance of shielding failure. Furthermore, the results are given that wind speed has effects on the protection angle and the rate of shielding failure by using the program to calculate it.
Keywords:double circuit  transmission line  lightning protection performance
点击此处可从《保鲜与加工》浏览原始摘要信息
点击此处可从《保鲜与加工》下载全文
设为首页 | 免责声明 | 关于勤云 | 加入收藏

Copyright©北京勤云科技发展有限公司  京ICP备09084417号