Comparison of femoral and auricular arterial blood pressure monitoring in pigs
Authors:Louise ME Bass BSc  BVMS  Member ACVSc    Dao-Yi Yu† MD  PhD  & Len K Cullen BVSc  PhD  Fellow ACVSc  Diplomate ECVAA
Institution:Department of Anaesthesia, Murdoch University Veterinary Hospital, Murdoch University, Perth, WA, Australia;
Department of Physiology and Pharmacology, Centre of Ophthalmology and Visual Science, Lions Eye Institute, Nedlands, WA, Australia
Abstract:Objective To compare arterial blood pressure measurements obtained from the femoral and auricular arteries in anaesthetized pigs. Study design Prospective experimental study. Animals Fifteen female Large White pigs were used weighing 21.3 ± 2.3 kg. Methods The pigs were anaesthetized with tiletamine/zolazepam and xylazine administered intramuscularly, and anaesthesia maintained with isoflurane delivered in oxygen/nitrogen. Arterial oxygen partial pressures were maintained between 11.3 and 13.3 kPa and PaCO2 between 4.6 and 6.0 kPa. Monitoring included electrocardiogram, capnography and invasive blood pressure. The auricular and femoral arteries were catheterized for continuous systolic (SAP), diastolic (DAP) and mean arterial pressure (MAP) measurements. Measurements were recorded every 15 minutes. Statistical analysis involved a Bland–Altman plot analysis. Results The mean difference ± confidence intervals between the femoral and the auricular arterial diastolic, systolic and mean blood pressure measurements during hypotension were 2 ± 7, 2 ± 5 and 2 ± 5 mmHg respectively. In conditions of normotension mean difference ± confidence intervals, of femoral and auricular arterial blood pressure measurements of diastolic, systolic and mean blood pressure were 4 ± 5, 3 ± 7 and 4 ± 4 mmHg respectively. In conditions of increased arterial blood pressure, mean difference ± confidence intervals, of femoral and auricular arterial blood pressure measurements of diastolic, systolic and mean blood pressure were 4 ± 5, 3 ± 8 and 4 ± 4 mmHg respectively. Conclusion Auricular artery catheterization is easier and quicker to perform. Pressure measurements from the auricular artery compared well with the femoral artery. Clinical relevance We found that auricular arterial blood pressures were similar to femoral arterial values under the conditions of this experiment. We did not test extremes of blood pressure or significant alterations in body temperature.
Keywords:arterial blood pressure  monitoring  pig  swine
本文献已被 ScienceDirect 等数据库收录!
设为首页 | 免责声明 | 关于勤云 | 加入收藏

Copyright©北京勤云科技发展有限公司  京ICP备09084417号