Quantification of reservoir bags as airway pressure-limiting devices in a nonrebreathing system |
| |
Authors: | Tamas D. Ambrisko Arnon Gal Jesus N. Sarol Ashley Mitek Christina Braun |
| |
Affiliation: | 1. Department of Veterinary Clinical Medicine, College of Veterinary Medicine, University of Illinois at Urbana-Champaign, Urbana, IL, USA;2. Illinois Biostatistics, Epidemiology and Research Design Core, Interdisciplinary Health Sciences Institute, University of Illinois at Urbana-Champaign, Urbana, IL, USA;3. Anaesthesiology and Perioperative Intensive-Care Medicine, Department for Companion Animals and Horses, University of Veterinary Medicine, Vienna, Austria |
| |
Abstract: | ObjectiveTo evaluate the influence of reservoir bag types, volumes and previous use on the peak pressures (Pmax) and the times to develop 30 cmH2O pressure (P30) within a nonrebreathing system with a closed adjustable pressure-limiting (APL) valve.Study designIn vitro study using three-way factorial design with repeated measure on one factor.SubjectsA total of 75 new anesthesia reservoir bags (five types, three volumes, five bags from each type × volume). The bag types were reusable latex (RL), disposable latex (DL) and three disposable neoprene (DN-1, DN-2 and DN-3).MethodsEach bag was tested three times (treatments): new, after prestretching and 1 week later. The bags were attached to a Bain system and anesthesia machine with closed APL valve and patient port with O2 flow 2 L minute–1 until Pmax was reached. The Pmax and time to reach P30 values were determined from recorded pressure traces. General linear mixed model analysis was used to examine the effects of bag type, volume and treatment. One-sided 95% upper prediction limits of Pmax were calculated to test the null hypothesis that predicted Pmax of new bags would be ≥ 50 cmH2O for each factor combination.ResultsRL bags were the least and DN-3 bags were the most compliant. Prestretching increased compliance in all bag types. Smaller bags of RL, DL and DN-1 were less compliant than larger ones. The predicted Pmax values were < 50 cmH2O only for DN-3 bags after prestretching. The time to reach P30 was critically low when using 0.5 L bags (median 17 seconds).Conclusions and clinical relevanceTo minimize the risk of barotrauma, highly compliant reservoir bags (e.g. DN-3) are recommended and reusable bags should be avoided. Bags should be prestretched before first use, 0.5 L bags should be avoided and fresh gas flow minimized. |
| |
Keywords: | anesthetic accident APL valve Bain circuit excessive airway pressure nonrebreathing system reservoir bag |
本文献已被 ScienceDirect 等数据库收录! |
|