Determination of moisture in Cheddar cheese by near infrared reflectance spectroscopy |
| |
Authors: | R L Wehling M M Pierce |
| |
Affiliation: | University of Nebraska, Department of Food Science and Technology, Lincoln 68583-0919. |
| |
Abstract: | Near infrared reflectance (NIR) spectroscopy was used to determine the moisture content of Cheddar cheese. Through multiple linear regression analysis, a 3-wavelength calibration was developed for use with a commercial filter monochromator instrument. For a validation set of 47 samples, the correlation coefficient squared (r2) between the NIR and oven moisture methods was 0.92, with a standard error of performance (SEP) of 0.38%. Sample temperature was found to significantly affect the spectral response; therefore, it was necessary to equilibrate all samples to a uniform temperature prior to NIR analysis. Aging may also affect the NIR characteristics of cheese, although it was possible to develop a successful calibration that encompassed a wide range of aging times. |
| |
Keywords: | |
|
|