摘    要:建立了水样品中氟蚁腙残留的超高效液相色谱-串联质谱检测方法。水样品用正己烷和丙酮的混合溶液提取,用UPLC-MS/MS测定。氟蚁腙在水中的平均回收率和RSD分别为91.8~93.2%和2.78~6.02%。该检测方法具有灵敏度高、快速、操作简单等特点,并可用于水样品中氟蚁腙的检测。

关 键 词:氟蚁腙  超高效液相色谱-串联质谱  

Simplified Method for Determination of Hydramethylnon Residues in Water using UPLC-MS/MS
Piao Xiuying,Guo Zijing,Zhou Yanming,Wang Xiaojun,Jiang Hui.Simplified Method for Determination of Hydramethylnon Residues in Water using UPLC-MS/MS[J].Pesticide Science and Administration,2012,33(10):27-29.
Authors:Piao Xiuying  Guo Zijing  Zhou Yanming  Wang Xiaojun  Jiang Hui
Institution:(Institute for the Control of Agrochemicals,Ministry of Agriculture,Beijing 100125,China)
Abstract:The analysis method of hydramethylnon in water was established using UPLC-MS/MS.The water sample were extracted by the mixture of hexane and acetone then determined by UPLC-MS/MS.The average recoveries rate and RSD of hydramethylnon in water were 91.8~93.2% and 2.78~6.02% respectively.The method was sensitive,rapid and simple so that reliable to determine the hydramethylnon residues in water.