首页 | 本学科首页   官方微博 | 高级检索  
     


Temperature as an indicator of landfill behavior
Authors:A. J. Crutcher  F. A. Rovers  E. A. McBean
Affiliation:1. Conestoga-Rovers and Associates Ltd., N2V 1C2, Waterloo, Ontario, Canada
2. Dept. of Civil Engineering, University of Waterloo, N2L 3G1, Waterloo, Ontario, Canada
Abstract:The utility of landfill temperature measurements both as a means of understanding landfill behavior and the interpretation of anomalous data points is explored by demonstration in a case study application. The availability of a pathway facilitating easy intrusion of atmospheric OZ into a landfill is shown to cause aerobic conditions and spontaneous combustion, during landfill pumping experiments. The landfill temperature measurements provide an effective means of isolating the extent of the problem.
Keywords:
本文献已被 SpringerLink 等数据库收录!