首页 | 本学科首页   官方微博 | 高级检索  
     检索      


Exposure of Gas Station Attendants to Methylcyclopentadienyl Manganese Tricarbonyl (MMT) Used in Gasoline
Authors:Keiloun  Mouna  Yang  Fan  Chau  Yiu K  Gagnon  France  Bouyahi  Bahiya  Rivard  Michèle  Kennedy  Greg  Normandin  Louise  Zayed  Joseph
Institution:1. Human Toxicology Research Group and Department of Environmental and Occupational Health, University of Montreal, Montreal, Quebec, Canada
2. Canada Center for Inland Waters, National Water Research Institute, Environment Canada, Burlington, Ontario, Canada
3. Department of Social and Preventive Medicine, Faculty of Medicine, University of Montreal, Montreal, Quebec, Canada
4. Ecole Polytechnique, University of Montreal, Montreal, Quebec, Canada
Abstract:

Methylcyclopentadienyl manganese tricarbonyl (MMT) is an organic derivative of manganese (Mn) used in Canada as an antiknock agent and octane enhancer in gasoline. In a recent study, we measured the atmospheric concentrations of MMT at selected outdoor sites in Montreal. Results ranged from 0.18 to 25 ng m-3 (expressed as Mn) and do not reflect personal exposure levels. The highest values were obtained at a gas station (mean of 12 ng m-3). By extension, evaluation of the personal exposure of gas station attendants constitutes a promising area of research. In an earlier study, the sampling method used allowed the possibility that the samples could have included ultra-fine particles, which may have passed through the filters used, and the chemical analysis used (neutron activation) did not discriminate between MMT and other Mn compounds. The present study aims to validate an improved sampling method and to assess personal exposure of gas station attendants to MMT. The MMT recovery of the new sampling method was found to be 91.6%. The exposure of 13 gas station attendants was measured on 1 to 6 occasions each (n = 32). They were working in two busy gas stations located in Montreal and they were asked to wear a portable pump for 2 hr. The air was pumped through two tubes in series filled with the adsorbent Tenax TA?, with glass wool plugs at both ends. The tubes were wrapped in aluminum foil and samples were analyzed for MMT by gas chromatograph-atomic emission detector (GC-AED). Results vary between 0.3 and 11.4 ng m-3, with a mean of 3.9 ng m-3. The highest values obtained in the first study may be due to the analytical techniques used previously, where detection of different Mn compounds other than MMT was possible. Since GC-AED is specific to MMT in the samples, the MMT found in air raises doubt as to the time required for the photodegradation of MMT.

Keywords:
本文献已被 SpringerLink 等数据库收录!
设为首页 | 免责声明 | 关于勤云 | 加入收藏

Copyright©北京勤云科技发展有限公司  京ICP备09084417号