首页 | 本学科首页   官方微博 | 高级检索  
     

双向偏心受压基础底面尺寸直接计算法
引用本文:王士杰 商合忠. 双向偏心受压基础底面尺寸直接计算法[J]. 河北农业大学学报, 1997, 20(4): 101-106
作者姓名:王士杰 商合忠
作者单位:[1]河北农大城乡建设学院 [2]保定市城市建设开发总公司
摘    要:本文给出了柱下基础双向偏心受压时基底尺寸的直接计算公式。可较快地求得充分利用地基承载能力、经济合理的基础底面积。

关 键 词:双向偏心受压 基底尺寸 地基承载力

A New Method to Direct Calculate the Size of Two-dimensional Eccentrically Loaded Footing
Wang Shijie, Zhao Chunsheng, Li Lihua, Yu Yunfei. A New Method to Direct Calculate the Size of Two-dimensional Eccentrically Loaded Footing[J]. Journal of Agricultural University of Hebei, 1997, 20(4): 101-106
Authors:Wang Shijie   Zhao Chunsheng   Li Lihua   Yu Yunfei
Abstract:A formula is shown in the paper to calculate directly the size of individual footing under columns for two-dimensional eccentric compression. The formula is able t0 work rapidly the economical and reasonable footing size, which can maximize the utility of bearing capacity.
Keywords:Individual footing under columns  Two-dimensional eccentrically load  Size of footing  Bearing capacity