首页 | 本学科首页   官方微博 | 高级检索  
     检索      

提高管道泄漏检测灵敏度和定位精度
引用本文:唐秀家.提高管道泄漏检测灵敏度和定位精度[J].油气储运,1997,16(4):27-29.
作者姓名:唐秀家
作者单位:北京大学
摘    要:研究流量测量误差对管道泄检测定位系统的精度有决定性影响,以腰轮流量计为例,讨论了流量计动态计量误差产生的原因,首交提出了采用三次样条插值拟合腰轮流量计误差流量曲线,动态修正以腰轮流量计滑流量为主的计量误差,能显著提高管道泄漏检测的灵敏度和泄漏定位精度。

关 键 词:管道  泄漏  检测  误差  油气管

Promoting Detection Sensitivety and Locating Accuracy for Pipeline Leakage
Tang Xiujia.Promoting Detection Sensitivety and Locating Accuracy for Pipeline Leakage[J].Oil & Gas Storage and Transportation,1997,16(4):27-29.
Authors:Tang Xiujia
Institution:Tang Xiujia
Abstract:Measurement error of flowrate affecting on accuracy of locating system of pipeline leakage is studied, for example of rotary flowmeter the cause of error resulting in dynamic metering is discussed, and first time to present a regression metering error curve by interpolation of third power of sample stripe, correcting dynamicly metering error causedby slide flow of rotary flowmeter, which can obviously promote the sensitivity of pipeline leakage detection and the locating accuracy.
Keywords:Pipeline  Leakage  Detection  Error  Correction  Methods  