Abstract: | The susceptibility of lactating bovine udder quarters fitted with a polyethylene intramammary device to infection was investigated. Following experimental challenge with Streptococcus agalactiae or Staphylococcus aureus, the incidence of infection was significantly (p less than 0.05) lower in intramammary device-fitted quarters compared to control quarters. In general, total foremilk and strippings milk somatic cell counts for intramammary device-fitted and control quarters were not significantly (p less than 0.05) different. Differential foremilk and strippings milk somatic cell counts were significantly (p less than 0.05) higher in samples from intramammary device-fitted quarters compared to control quarters. |