首页 | 本学科首页   官方微博 | 高级检索  
     检索      


Correlation analysis between visualization of hemorrheologic changes and platelet function in patients with acute coronary syndrome after percutaneous coronary intervention
Authors:WANG Jia-qi  LIU Jian-gang  WANG Cheng-long
Institution:Center of Cadiovascular Diseases, Xiyuan Hospital, China Academy of Chinese Medicine, Institute of Cardiovascular Diseases, China Academy of Chinese Medicine,Beijing 100091, China.
Abstract:AIM:To intuitionally observe the characteristics of blood rheology in the patients with acute coronary syndrome (ACS) after percutaneous coronary intervention (PCI) for 1 year to 3 years by micro-channel array flow analyzer (MC-FAN) combined with other platelet function indexes, and to explore the correlations between the test results of MC-FAN and platelet function. METHODS:This study brought 74 patients with ACS after PCI for 1 year to 3 years into test group, and 21 healthy subjects were enrolled as normal group. The levels of platelet aggregation test (PAgT), platelet adhesiveness test (PAdT), P-selectin, platelet-derived growth factor BB (PDGF-BB) and von Willebrand factor (vWF) were detected. MC-FAN HR300 was used to detect the transiting time (MC-FAN TT) of the blood passing through the model body capillaries. The differences of the test results between the 2 groups were compared, and the correlations between the results of MC-FAN and platelet function in the patients with ACS after PCI were also explored. RESULTS:Compared with normal group, the MC-FAN TT in test group was prolonged (P<0.01), the ability of erythrocyte deformation was weakened, and the leukocyte attaching the vascular wall and platelet adhesion and aggregation relatively increased. The levels of PAgT, PAdT, P-selectin and PDGF-BB in test group were all higher than those in normal group (P<0.01). No difference of vWF between the 2 groups was observed. The intergroup correlation analysis showed that there were correlations between MC-FAN TT and platelet function, in which 10 μL MC-FAN TT and 30 μL MC-FAN TT had the most significant correlation with P-selectin (r=0601, P<0.01; r=0334, P<0.01), 60 μL MC-FAN TT had the most significant correlation with PAgT (r=0527, P<0.01), and 100 μL MC-FAN TT had the most significant correlation with PAdT (r=0. 815, P<0.05). CONCLUSION:The visualization of hemorrheologic changes and platelet function in the patients with ACS after PCI are abnormal.There are correlations between MC-FAN TT and platelet function.The results of MC-FAN can objectively evaluate the blood rheology of the patients, and provide the reference for clinical treatment.
Keywords:Acute coronary syndrome  Percutaneous coronary intervention  Visualization  Platelet function  Hemorheology  
点击此处可从《园艺学报》浏览原始摘要信息
点击此处可从《园艺学报》下载免费的PDF全文
设为首页 | 免责声明 | 关于勤云 | 加入收藏

Copyright©北京勤云科技发展有限公司  京ICP备09084417号