首页 | 本学科首页   官方微博 | 高级检索  
     


Assessment of myocardial dysfunction in septic rats with conventional echocardiography and tissue Doppler imaging
Authors:SHAN Guang-hua  XU Ya-qian  TANG Xiang-xu  LI Hong-mei  WANG Yan-ping  LI Kai-ying  XING Yun  DAI Xiao-meng  YANG Duo-meng  Lü Xiu-xiu  LU Da-xiang  WANG Hua-dong
Affiliation:1.Department of Cardiovascular Medicine, The First Affiliated Hospital of Jinan University;2.Department of Pathophysiology, Key Laboratory of Pathophysiology of National Administration of Traditional Chinese Medicine, School of Medicine, Jinan University, Guangzhou 510632, China. E-mail: owanghd@jnu.edu.cn
Abstract:AIM To compare various conventional and tissue Doppler echocardiographic indexes to assess their accuracy to detect left ventricular (LV) intrinsic systolic and diastolic dysfunction in septic rats. METHODS Twenty-two SD rats were randomly divided into 2 groups: sham group and sepsis group, with 11 rats in each group. A model of sepsis was established by cecal ligation and puncture (CLP). Serum tumor necrosis factor-α (TNF-α) level, and myocardial intercellular adhesion molecule-1 (ICAM-1) and vascular cell adhesion molecule-1 (VCAM-1) expression were determined by ELISA and Western blot. The LV systolic and diastolic functions were analyzed by isolated heart Langendorff perfusion technique, conventional echocardiography and tissue Doppler imaging. RESULTS Compared with sham group, the serum TNF-α level, and LV ICAM-1 and VCAM-1 expression were increased significantly, while LV ±dp/dtmax, stroke volume and LV end-diastolic volume were markedly decreased at 6 h after CLP. Moreover, compared with sham group, mitral inflow peak E and A wave velocities as well as early-diastolic peak velocities (E' wave) and late-diastolic peak velocities (A' wave) of the mitral annulus were reduced significantly in sepsis group at 6 h after CLP. In contrast, no significant difference in LV ejection fraction and E/E' ratio between sham group and sepsis group was observed. Further investigation revealed that peak E' wave and A' wave velocities were positively correlated with -dp/dtmax (r=0.460 and r=0.520, P<0.05). CONCLUSION At the early stage of sepsis, tissue Doppler echocardiography is a useful technique to assess LV diastolic dysfunction, and peak E' and A' wave velocities may be the sensitive indexes to detect LV intrinsic diastolic dysfunction.
Keywords:Sepsis  Myocardial dysfunction  Isolated heart perfusion  Tissue Doppler imaging  
点击此处可从《园艺学报》浏览原始摘要信息
点击此处可从《园艺学报》下载全文
设为首页 | 免责声明 | 关于勤云 | 加入收藏

Copyright©北京勤云科技发展有限公司  京ICP备09084417号