首页 | 本学科首页   官方微博 | 高级检索  
     检索      


Effect of sample type, and timing of assay, on feline blood potassium concentration
Authors:Gunn-Moore Danièlle A  Reed Nicola  Simpson Kerry E  Milne Elspeth M
Institution:Royal (Dick) School of Veterinary Studies Hospital for Small Animals, University of Edinburgh, Easter Bush Veterinary Centre, Roslin, Midlothian, Scotland EH25 9RG, UK. danielle.gunn-moore@ed.uk
Abstract:Blood samples were collected from 41 cats presented for pre-anaesthetic assessments, routine geriatric screening, or re-assessment of ongoing chronic medical disorders. Samples were either left to clot or anticoagulated with lithium heparin, then assessed for their potassium concentration within 1h of collection, and again after remaining in contact with their cell pellet for 48 h. There was a significantly higher potassium concentration in the serum samples compared to the plasma samples, both in the basal and 48-h samples (although this difference was most marked in the basal samples). Ageing of both serum and plasma samples also resulted in an increase in the potassium concentration when compared with the basal values for each sample type. The mean difference (basal serum minus basal plasma) in potassium concentration was 0.47 mmol/l. While it is probable that the potassium came from either leukocytes and/or thrombocytes the mean total leukocyte count and the mean thrombocyte count were below the upper limit of the reference intervals for our laboratory and the rise in the potassium level did not appear to be directly related to either of these values.
Keywords:
本文献已被 ScienceDirect PubMed 等数据库收录!
设为首页 | 免责声明 | 关于勤云 | 加入收藏