Electroencephalographic Power Spectrum Analysis as a Monitor of Anesthetic Depth in Horses
Authors:KLAUS OTTO DR  MED VET CHARLES E SHORT DVM  MS  Dipiomate ACVA
Institution:Department of Clinical Sciences, College of Veterinary Medicine, Cornell University, Ithaca, New York 14850.
Abstract:Electroencephalographic (EEG) power spectrum analysis was performed in 18 conscious, adult horses for evaluation as control values for EEG data obtained during anesthesia. Computer-processed total amplitudes for the frequency range 0 to 32 Hz were mainly between 400 and 600 microV, with 80% spectral edge frequency between 16.6 and 32.5 Hz. The highest electrical activity was in the delta band (41.3 +/- 4.4% of total amplitude); there was a less pronounced activity in the beta (34.2 +/- 5.2%), theta (13.6 +/- 1.5%), and alpha (10.0 +/- 1.0%) bands. The applicability of EEG power spectrum analysis as a guide to depth of anesthesia was evaluated in four horses by comparing simultaneously recorded EEG data and clinical signs of anesthesia. Global changes in cerebrocortical electrical activity were detected with a single, monopolar (left frontoatlanto-occipital) EEG lead. Increasing depth of halothane anesthesia was accompanied by a pronounced shift in EEG activity from beta to theta and delta frequency bands, a decrease in 80% spectral edge frequency from 21.5 +/- 2.4 Hz to 12.6 +/- 2.2 Hz, a reduction in the beta/delta ratio of fractional amplitudes from 2.37 +/- 0.84 to 0.49 +/- 0.04, and a slight inconsistent increase in total amplitude from 96.1 +/- 37.3 microV to 185.5 +/- 53 microV. These results show that changes in the clinical signs of anesthetic depth in horses can be described numerically by use of EEG power spectrum analysis.
Keywords:
设为首页 | 免责声明 | 关于勤云 | 加入收藏

Copyright©北京勤云科技发展有限公司  京ICP备09084417号