Institution:1. Department of Chemical and Agricultural Engineering and Technology, University of Girona, Campus Montilivi s/n, 17071 Girona, Spain;2. Department of Agricultural and Forestry Engineering, University of Lleida, Avda. Rovira Roure 177, 25198 Lleida, Spain;1. Biosystems Engineering Department, School of Agriculture, Shiraz University, Iran;2. Tasmanian Institute of Agriculture, University of Tasmania, Australia;3. School of Mechanical, Medical & Process Engineering, Faculty of Engineering, QUT, QLD, Australia;4. School of Mechanical Engineering, Shiraz University, Shiraz, Iran;1. College of Engineering, Northeast Agricultural University, Harbin 150030, China;2. College of Biological and Agricultural Engineering, Jilin University, Changchun 130022, China;1. International Logistics and Productivity Improvement Laboratory, Arizona State University, Tempe, AZ 85287-5906, USA;2. Universidad Autonoma de Occidente, Colombia;1. College of Hydraulic Science and Engineering, Yangzhou University, Yangzhou 225009, China;2. Engineering Research Center of High−efficiency and Energy−saving Large Axial Flow Pumping Station of Jiangsu Province, Yangzhou University, Yangzhou 225009, China;3. College of Water Conservancy and Hydropower Engineering, Hohai University, Nanjing 210098, China;4. China Institute of Water Resources and Hydropower Research, State Key Laboratory of Simulation and Regulation of Water Cycle in River Basin, Beijing 100038, China;1. Faculty of Modern Agriculture Engineering, Kunming University of Science and Technology, Kunming 650000, China;2. School of Energy and Environment Science, Yunnan Normal University, Kunming 650000, China;3. School of Aeronautics and Astronautics, Sun Yat-Sen University, Guangzhou 510275, China
Abstract:A supervisory control and data acquisition (SCADA) system has been developed to monitor and control microirrigation system performance. The microirrigation system had four types of filtration units and, placed after each one of them, twenty-four irrigation laterals using urban effluents. The SCADA system activated the irrigation system and the backwashing filter procedure. It also monitored pressure and flow at the filtration units and irrigation laterals to assess clogging problems and measure the consumed water volume in filter backwashing. The system was also prepared for remote access via Internet.
Keywords:
本文献已被 ScienceDirect 等数据库收录!
设为首页 | 免责声明 | 关于勤云 | 加入收藏

Copyright©北京勤云科技发展有限公司  京ICP备09084417号