首页 | 本学科首页   官方微博 | 高级检索  
     


Quantification of groundwater recharge and evapotranspiration along a semi-arid wetland transect using diurnal water table fluctuations
Authors:JIA Wuhui
Affiliation:School of Water Resources and Environment,China University of Geosciences(Beijing),Beijing 100083,China;Xi'an Center of Geological Survey,China Geological Survey,Xi'an 710054,China;Institute of Disaster Prevention and Ecological Restoration,Xi'an Jiaotong University,Xi'an 710049,China;Chinese Academy of Geological Sciences,Beijing 100037,China
Abstract:Groundwater is a vital water resource in arid and semi-arid areas. Diurnal groundwater table fluctuations are widely used to quantify rainfall recharge and groundwater evapotranspiration (ETg). To assess groundwater resources for sustainable use, we estimated groundwater recharge and ETg using the diurnal water table fluctuations at three sites along a section with different depths to water table (DWT) within a wetland of the Mukai Lake in the Ordos Plateau, Northwest China. The water table level was monitored at an hourly resolution using a Keller DCX-22A data logger that measured both the total pressure and barometric pressure, so that the effect of barometric pressure could be removed. At this study site, a rapid water table response to rainfall was observed in two shallow wells (i.e., Obs1 and Obs2), at which diurnal water table fluctuations were also observed over the study period during rainless days, indicating that the main factors influencing water table variation are rainfall and ETg. However, at the deep-water table site (Obs3), the groundwater level only reacted to the heaviest rainfalls and showed no diurnal variations. Groundwater recharge and ETg were quantified for the entire hydrological year (June 2017-June 2018) using the water table fluctuation method and the Loheide method, respectively, with depth-dependent specific yields. The results show that the total annual groundwater recharge was approximately 207 mm, accounting for 52% of rainfall at Obs1, while groundwater recharge was approximately 250 and 21 mm at Obs2 and Obs3, accounting for 63% and 5% of rainfall, respectively. In addition, the rates of groundwater recharge were mainly determined by rainfall intensity and DWT. The daily mean ETg at Obs1 and Obs2 over the study period was 4.3 and 2.5 mm, respectively, and the main determining factors were DWT and net radiation.
Keywords:groundwater recharge  groundwater evapotranspiration  water table fluctuation  semi-arid region  Ordos Plateau  
本文献已被 CNKI 万方数据 等数据库收录!
点击此处可从《干旱区科学》浏览原始摘要信息
点击此处可从《干旱区科学》下载全文
设为首页 | 免责声明 | 关于勤云 | 加入收藏

Copyright©北京勤云科技发展有限公司  京ICP备09084417号