Abstract:Using a single channel electronic cell counter and attached particle size analyzer, leukocyte size distribution histograms were determined on canine, feline, bovine, and equine blood diluted with chloride-based diluent and treated with a conventional stromatolysin. Histograms were usually unimodal, but a few were bimodal. Mean values for mean lysed leukocyte particle volume were 49.2, 51.1, 55.4, and 65.0 fl for canine, feline, equine, and bovine blood, respectively. From inspection of histograms, a lower threshold of 30 fl referenced to latex spheres was interpreted to be appropriate for counting leukocytes of these four species simultaneously. Debris below the threshold was seen in many samples and was usually separated from the leukocyte population by a valley touching the histogram baseline at the threshold channel. Debris resulted in a visually detectable threshold failure by extending considerably into the leukocyte size range in 9% of feline, 9% of canine, and 7% of bovine samples. It is recommended that careful establishment of the lower counting threshold will minimize frequency and severity of leukocyte count error associated with failure to exclude debris.