Test Study on the Small Span-to Depth Ratio Seismic Coupling Beams with Low Reinforcement Rate by New Reinforcement Scheme
作者姓名:FU Jian-ping  ZHAO Jie-lin  CAO Yun-feng  BAI Shao-liang
摘    要:Coupling beams are the key elements of plastic energy dissipation mechanisms in coupled walls.However,the design of the small span-to-depth ratio coupling beams with high ductility is still one of the problems not solved effectively in domestic and foreign seismic reinforced concrete structure design.The research group,where the authors of this paper are,brings forward a new reinforcement scheme with adding diagonal and rhombic bars to traditional reinforcement in the foundation.Test results prove that it is an effective way to solve the problems for it has good seismic performance and is easy to be constructed.This paper puts great emphasis on introducing the trial results and principal rules that are deduced from the test results of second set of specimens with low reinforcement rate.

关 键 词:reinforced  concrete  seismic  coupled  walls  coupling  beams  with  small  span  to  depth  ratio
修稿时间:2003/8/25 0:00:00

Test Study on the Small Span-to Depth Ratio Seismic Coupling Beams with Low Reinforcement Rate by New Reinforcement Scheme
FU Jian-ping,ZHAO Jie-lin,CAO Yun-feng,BAI Shao-liang.Test Study on the Small Span-to Depth Ratio Seismic Coupling Beams with Low Reinforcement Rate by New Reinforcement Scheme[J].Storage & Process,2004(1):50-54.
Authors:FU Jian-ping  ZHAO Jie-lin  CAO Yun-feng  BAI Shao-liang
Abstract:Coupling beams are the key elements of plastic energy dissipation mechanisms in coupled walls.However,the design of the small span-to-depth ratio coupling beams with high ductility is still one of the problems not solved effectively in domestic and foreign seismic reinforced concrete structure design.The research group,where the authors of this paper are,brings forward a new reinforcement scheme with adding diagonal and rhombic bars to traditional reinforcement in the foundation.Test results prove that it is an effective way to solve the problems for it has good seismic performance and is easy to be constructed.This paper puts great emphasis on introducing the trial results and principal rules that are deduced from the test results of second set of specimens with low reinforcement rate.
Keywords:reinforced concrete  seismic coupled walls  coupling beams with small span to depth ratio