Choosing optimal design depth for surface irrigation systems |
| |
Authors: | J.Mohan Reddy Wayne Clyma |
| |
Affiliation: | Department of Agricultural and Chemical Engineering, Colorado State University, Fort Collins, CO 80523 U.S.A. |
| |
Abstract: | The surface irrigation system design was formulated as a mathematical programming problem. The minimum cost of a furrow irrigation system for a hypothetical case was calculated for different design depths (25, 51, 76, 102 and 127 mm). The crop yields and net returns were simulated for the given design depths. A design (depletion) depth of 51 mm was found optimal under the given conditions. |
| |
Keywords: | |
本文献已被 ScienceDirect 等数据库收录! |
|