首页 | 本学科首页   官方微博 | 高级检索  
     检索      


Mechanical measures of uncooked beef longissimus muscle can predict sensory panel tenderness and Warner-Bratzler shear force of cooked steaks
Authors:Timm R R  Unruh J A  Dikeman M E  Hunt M C  Lawrence T E  Boyer J E  Marsden J L
Institution:Department of Animal Sciences and Industry, Kansas State University, Manhattan 66506, USA.
Abstract:Two experiments were conducted to investigate mechanical measures of tenderness on uncooked USDA Select longissimus muscle as a means to predict Warner-Bratzler shear force (WBSF) and trained sensory panel tenderness (SPT) of cooked steaks. In Exp. 1, strip loins (n = 24) were aged 14 d postmortem and fabricated into steaks (2.54 cm). Medial, center, and lateral locations within uncooked steaks were evaluated by a plumb bob device and correlated with WBSF and SPT of cooked steaks. In Exp. 2, 24 strip loins were used to evaluate how well plumb bob and needle probe devices used on uncooked steaks predicted WBSF and SPT of cooked steaks. At 2 d postmortem, two steaks were fabricated from the anterior end. One uncooked steak (2.54 cm) was assigned to the plumb bob treatment and the other uncooked steak (5.08 cm) was assigned to needle probe treatment. At 14 d postmortem, one uncooked steak (5.08 cm) was assigned to needle probe treatment, a second uncooked steak (2.54 cm) was assigned to plumb bob treatment, whereas the remaining steaks (2.54 cm) were cooked and evaluated by a trained sensory panel and WBSF device. In Exp. 1, average plumb bob values were negatively correlated (P < 0.05) to average SPT scores (r = -0.48). However, correlations between WBSF and plumb bob values for medial, lateral, and average of all sections were not significant (P > 0.05). In Exp. 2, regression models to predict SPT from needle probe and plumb bob measurements individually taken at 2 d postmortem had R2 of 0.54 and 0.51, respectively. Combining needle probe and plumb bob measurements resulted in an R2 of 0.76; when quadratic terms for both variables were in the model, the R2 was 0.80. Regressing needle probe and plumb bob measurements at 2 d postmortem with WBSF produced R2 values of 0.51 and 0.45, respectively. If linear terms of both probes were combined to predict WBSF, the R2 increased to 0.77. An equation to predict WBSF, including both the linear and quadratic terms of needle probe and plumb bob measurements, resulted in an R2 of 0.84. Using plumb bob and needle probe devices on uncooked longissimus muscle at 2 d postmortem can predict cooked WBSF and SPT of USDA Select Grade steaks at 14 d postmortem.
Keywords:
本文献已被 PubMed 等数据库收录!
设为首页 | 免责声明 | 关于勤云 | 加入收藏

Copyright©北京勤云科技发展有限公司  京ICP备09084417号