首页 | 本学科首页   官方微博 | 高级检索  
     检索      


Cardiovascular responses to transvenous electrical cardioversion of atrial fibrillation in anaesthetized horses
Authors:Stijn Schauvliege DVM    Gunther van Loon† DVM  PhD  Diplomate ECVIM    Dominique De Clercq† DVM  PhD    Lindsey Devisscher DVM    Piet Deprez† DVM  PhD  Diplomate ECBHM  & Frank Gasthuys DVM  PhD  Diplomate ECVAA
Institution:Faculty of Veterinary Medicine, Department of Surgery and Anaesthesia of Domestic Animals, Ghent University, Salisburylaan, Merelbeke, Belgium;Faculty of Veterinary Medicine, Department of Large Animal Internal Medicine, Ghent University, Salisburylaan, Merelbeke, Belgium
Abstract:ObjectiveTo examine the influence of direct current shock application in anaesthetized horses with atrial fibrillation (AF) and to study the effects of cardioversion to sinus rhythm (SR).Study designProspective clinical study.AnimalsEight horses successfully treated for AF (transvenous electrical cardioversion after amiodarone pre-treatment).MethodsCardioversion catheters and a pacing catheter were placed under sedation detomidine 10 μg kg?1 intravenously (IV)]. After additional sedation (5–10 μg kg?1 detomidine, 0.1 mg kg?1 methadone IV), anaesthesia was induced with ketamine, 2.2 mg kg?1 and midazolam, 0.06 mg kg?1 (IV) in a sling and maintained with isoflurane in oxygen. Flunixin meglumine, 1.1 mg kg?1, was administered IV. Shocks were delivered as biphasic truncated exponential waves, synchronized with the R-wave of the electrocardiogram. Monitoring included pulse oximetry, electrocardiography, capnography, inhalational anaesthetic agent concentration, arterial blood pressure, LiDCO and PulseCO cardiac index (CI) and arterial blood gases. Values before and after the first unsuccessful shock and before and after cardioversion to SR were compared.ResultsValues before the first shock were comparable to reported values in healthy, isoflurane anaesthetized horses. Reliable CI measurements could not be obtained using the PulseCO technique. Intermittent positive pressure ventilation was required in most horses (bradypnea and/or PaCO2 >8 kPa, 60 mmHg), while dobutamine was administered in two horses (0.3–0.5 μg kg?1 minute?1). After the 1st unsuccessful shock application, systolic arterial pressure (SAP) was decreased (p = 0.025), other recorded values were not influenced (CI measurements not available for this analysis). SR was associated with increases in CI (p = 0.039) and stroke index (p = 0.002) and a decrease in SAP (p = 0.030).Conclusions and clinical relevanceDespite the presence of AF, cardiovascular function was well maintained during anaesthesia and was not affected by shock application. Cardiac index and stroke index increased and SAP decreased after cardioversion.
Keywords:atrial fibrillation  cardiovascular function  horses  transvenous electrical cardioversion
本文献已被 ScienceDirect 等数据库收录!
设为首页 | 免责声明 | 关于勤云 | 加入收藏

Copyright©北京勤云科技发展有限公司  京ICP备09084417号