首页 | 本学科首页   官方微博 | 高级检索  
     检索      


Evaluation of Pulse Oximetry as a Continuous Monitoring Technique in Critically Ill Dogs in the Small Animal Intensive Care Unit
Authors:Nancy B Fairman DVM  MS
Institution:H6/380 Clinical Science Center, Department of Pulmonary and Critical Care Medicine, University of Wisconsin Hospital, 600 Highland Avenue, Madison, Wisconsin 53792
Abstract:To assess the clinical applicability of pulse oximetry in the intensive care setting, a comparison was made of arterial hemoglobin saturation values determined by in vitro oximetry (SaO2) and pulse oximetry (SpO2) in 21 critically ill dogs. Single SaO2 measurements were compared to simultaneously obtained SpO2 readings. The correlation between these two methods was statistically significant (r = 0.8944, p = 0.0001). In addition, heart rates read by the pulse oximeter were compared to simultaneously obtained electrocardiograms (ECG). The correlation between these two methods was statistically significant (r = 0.9966, p = 0.0001). The pulse oximeter was easy to use, and recorded trends in oxygenation virtually instantaneously. Pulse oximetry appears to be an accurate and practical technique for the continuous non-invasive monitoring of oxygenation in critically ill dogs in the intensive care unit.
Keywords:pulse oximetry  hemoglobin oxygen saturation  dogs  critical care