首页 | 本学科首页   官方微博 | 高级检索  
     


Time-specific intraocular pressure curves in Rhesus macaques (Macaca mulatta) with laser-induced ocular hypertension
Authors:Ollivier F J  Brooks D E  Kallberg M E  Sapp H L  Komáromy A M  Stevens G R  Dawson W W  Sherwood M B  Lambrou G N
Affiliation:Department of Small Animal Clinical Sciences, College of Veterinary Medicine,;Department of Statistics, College of Medicine and;Department of Ophthalmology, College of Medicine, University of Florida, Gainesville, Florida, USA,;CIBA Vision, Basel, Switzerland
Abstract:Objective To detect and categorize time‐specific variations in daytime intraocular pressure (IOP) found in Rhesus monkeys with laser‐induced ocular hypertension. Procedures Ten male monkeys with argon laser‐induced ocular hypertension in one eye were anesthetized with ketamine hydrochloride, and the IOP measured in both eyes at 7 a.m., 7.30 a.m., and then hourly until 1 p.m. with a Tonopen? XL applanation tonometer. Intraocular pressure time profiles for both eyes in each animal were developed. The means ± SD of the IOPs for both eyes were calculated for the whole 6‐h study period, and the values compared statistically. The difference between the lasered eye mean IOP standard deviation and the normal eye mean IOP standard deviation for each animal during the 6‐h follow‐up was also calculated and compared. Results Mean IOP (± SD) in the glaucoma and normal eyes for the 10 animals during the 6‐h study was 32.6 ± 2.5 and 14.9 ± 2.5 mmHg, respectively. The IOP was significantly higher in the experimental eye than in the normal eye (P = 0.0008). The mean IOP in the lasered eye did not significantly change during the study period, whereas a slight but significant increase in IOP of the normal eye over the study period was recorded (P = 0.003). The variance in IOP in the hypertensive eyes was considerably greater than that in the untreated control eyes. From 7 a.m. to 1 p.m. the IOP declined in five eyes and increased in the other five eyes with laser‐induced ocular hypertension. Conclusions The time‐specific IOP variation pattern in the daytime in the laser treated eyes is significantly greater than the variation in the normotensive eyes. This shows that in order to detect statistical differences between IOP variations induced by an IOP‐reducing drug, and the exaggerated spontaneous IOP variations present in the laser‐induced hypertensive eye, sufficient animals should be included in any study. Understanding the time‐specific IOP variation present in a group of monkeys with laser‐induced ocular hypertension is essential prior to using the model for the evaluation of IOP‐reducing drugs.
Keywords:intraocular pressure    ocular hypertension    Rhesus macaques
本文献已被 PubMed 等数据库收录!
设为首页 | 免责声明 | 关于勤云 | 加入收藏

Copyright©北京勤云科技发展有限公司  京ICP备09084417号