首页 | 本学科首页   官方微博 | 高级检索  
     检索      


Evaluating the Validity of a Nitrate Quick Test in Different Chinese Soils
Authors:YUE Xian-Lu  LI Fei  HU Yun-Cai  ZHANG Huai-Zhi  JI Hong-Jie  ZHANG Wei-Li and U SCHMIDHALTER
Institution:Chair of Plant Nutrition, Technische Universitaät Mäunchen, Emil-Ramann-Str. 2, Freising D-85350, Germany;Institute of Agricultural Resources and Regional Planning, Chinese Academy of Agricultural Sciences, Beijing 100081, China;Chair of Plant Nutrition, Technische Universitaät Mäunchen, Emil-Ramann-Str. 2, Freising D-85350, Germany;Chair of Plant Nutrition, Technische Universitaät Mäunchen, Emil-Ramann-Str. 2, Freising D-85350, Germany;Institute of Agricultural Resources and Regional Planning, Chinese Academy of Agricultural Sciences, Beijing 100081, China;Institute of Agricultural Resources and Regional Planning, Chinese Academy of Agricultural Sciences, Beijing 100081, China;Institute of Agricultural Resources and Regional Planning, Chinese Academy of Agricultural Sciences, Beijing 100081, China;Chair of Plant Nutrition, Technische Universitaät Mäunchen, Emil-Ramann-Str. 2, Freising D-85350, Germany
Abstract:Because laboratory tests are expensive and time-consuming and may not be available to farmers,soil nitrate quick tests are uired for optimal nitrogen management strategies in China to increase nitrogen use effciency and to reduce nitrogen losses.A total328 soil samples were collected at different soil depths from 225 sites in China,which covered a wide range of climatic and geographicions,soil types,croplands and soil textures,to evaluate the suitability of a quick reflectometer test method for analysing soil NO3--Na wide range of soil NO3-concentrations,soil types and cropping systems in China,mainly by comparison of soil NO3--N assessed by uick-test method(a reflectometer)and a standard laboratory method,i.e.,high-performance liquid chromatography(HPLC).The lectometer showed excellent agreement with the laboratory HPLC method with regard to soil nitrate contents for all analysed il samples.The linear regression had slopes of 1±0.08 and intercepts of±1.38 mg NO3--N L-1 among different soil types and plands.Compared with the 1:1 lines,the regression analysis for each soil type showed statistically significant but small differences slope;the relative difference between the values measured using the two analytical systems varied from-8%to 6%,and there were differences in intercept except for paddy soil.The reflectometer showed adequate,statistically significant precision in determining il nitrate contents,and it could therefore be directly used instead of the laboratory methods for soil NO3--N measurement in China.y Words:dilution,N recommendation,nitrate test strip,reflectometer,soil NO3--N
Keywords:dilution  N recommendation  nitrate test strip  reflectometer  soil NO3--N
本文献已被 CNKI ScienceDirect 等数据库收录!
点击此处可从《土壤圈》浏览原始摘要信息
点击此处可从《土壤圈》下载免费的PDF全文
设为首页 | 免责声明 | 关于勤云 | 加入收藏

Copyright©北京勤云科技发展有限公司  京ICP备09084417号