首页 | 本学科首页   官方微博 | 高级检索  
     


Experimental evaluation of four airway devices in anaesthetized New Zealand White rabbits
Authors:Sandra Wenger  Désirée Müllhaupt  Stefanie Ohlerth  Sarah Prasse  Karina Klein  Bianca da Silva Valente  Martina Mosing
Affiliation:1. Clinic for Zoo Animals, Exotic Pets and Wildlife, Vetsuisse Faculty, University of Zurich, Zurich, Switzerland;2. Clinic for Diagnostic Imaging, Vetsuisse Faculty, University of Zurich, Zurich, Switzerland;3. Division of Anaesthesiology, Equine Department, Vetsuisse Faculty, University of Zurich, Zurich, Switzerland;4. Musculoskeletal Research Unit, Equine Department, Vetsuisse Faculty, University of Zurich, Zurich, Switzerland
Abstract:

Objective

To compare airway management during induction of anaesthesia, spontaneous ventilation (SV) and controlled mechanical ventilation (CMV), using an endotracheal tube (ETT), laryngeal mask (LM), rabbit-specific supraglottic airway device (v-gel) or facemask (FM).

Study design

Prospective randomized crossover experiment.

Animals

Ten New Zealand White rabbits.

Methods

After premedication, rabbits were randomly allocated to four groups: 1) ETT; 2) LM; 3) v-gel or 4) FM. The required dose of propofol, duration and number of attempts to place an airway device and leakage during SV and CMV at different peak inspiratory pressures (6, 10, 12, 14 and 16 cmH2O) were recorded. Computed tomography (CT) of the head, neck and abdomen were performed before and after CMV.

Results

Significantly less propofol and time [2.0 ± 0.5 mg kg?1, 82 ± 34 seconds, p < 0.001] were needed to place the FM compared to the three other groups [v-gel 5.1 ± 2.1 mg kg?1, 302 ± 124 seconds; LM 4.8 ± 1.2 mg kg?1, 275 ± 89 seconds; ETT 5.5 ± 1.4 mg kg?1, 315 ± 147 seconds]. A leak > 25% of the tidal volume occurred at the lowest pressure in FM [median (range), 6 (6–8) cmH2O], which was significantly lower than with v-gel [16 (6–no leak at 16) cmH2O], LM [>16 (6–no leak at 16)] or ETT [>16 (no leak at 16) cmH2O] (p < 0.001). On CT images, the height and width of the larynx were significantly smaller with v-gel in comparison to FM and LM (p = 0.004). A significant increase in the amount of gas in the stomach (p = 0.007), but not gastric volume, was detected in FM and LM.

Conclusions and clinical relevance

The v-gel is a practical alternative to LM and ETT for airway management and CMV, but can compress the larynx. The FM is easily placed, but significant leakage occurs during CMV.
Keywords:endotracheal intubation  facemask  laryngeal mask  rabbit  v-gel
本文献已被 ScienceDirect 等数据库收录!
设为首页 | 免责声明 | 关于勤云 | 加入收藏