首页 | 本学科首页   官方微博 | 高级检索  
     

The Model of Water and Steam to Real-time Simulation for Supercritical Fossil Power Unit
引用本文:LIU Yuan-peng,WANG Guang-jun. The Model of Water and Steam to Real-time Simulation for Supercritical Fossil Power Unit[J]. 保鲜与加工, 2005, 0(10): 46-49
作者姓名:LIU Yuan-peng  WANG Guang-jun
作者单位:College of Power Engineering, Chongqing University, Chongqing 400030, China
摘    要:Based on the general thermodynamic theory,a mathematical model for thermodynamic parameters of hot-shot steam is derived,it includes the formula of specific enthalpy,specific volume,specific heat at constant pressure and specific entropy.The specific enthalpy formula of steam with a pressure range from 0 MPa to 90 MPa and the specific volume formula of steam with a pressure range from 0 MPa to 40 MPa within permission error of the International Steam Skeleton Tables in 1985,and that all the model with a temperature range from 273.15 K to 1 073.15 K.The model is applied to real-time simulation for supercritical fossil power unit and convenience in application of engineering.

关 键 词:water and steam   model   supereritieal fossil power unit   real-time simulation
收稿时间:2005-05-17
修稿时间:2005-05-17

The Model of Water and Steam to Real-time Simulation for Supercritical Fossil Power Unit
LIU Yuan-peng,WANG Guang-jun. The Model of Water and Steam to Real-time Simulation for Supercritical Fossil Power Unit[J]. Storage & Process, 2005, 0(10): 46-49
Authors:LIU Yuan-peng  WANG Guang-jun
Affiliation:College of Power Engineering, Chongqing University, Chongqing 400030, China
Abstract:Based on the general thermodynamic theory,a mathematical model for thermodynamic parameters of hot-shot steam is derived,it includes the formula of specific enthalpy,specific volume,specific heat at constant pressure and specific entropy.The specific enthalpy formula of steam with a pressure range from 0 MPa to 90 MPa and the specific volume formula of steam with a pressure range from 0 MPa to 40 MPa within permission error of the International Steam Skeleton Tables in 1985,and that all the model with a temperature range from 273.15 K to 1 073.15 K.The model is applied to real-time simulation for supercritical fossil power unit and convenience in application of engineering.
Keywords:water and steam   model   supereritieal fossil power unit   real-time simulation
点击此处可从《保鲜与加工》浏览原始摘要信息
点击此处可从《保鲜与加工》下载全文
设为首页 | 免责声明 | 关于勤云 | 加入收藏

Copyright©北京勤云科技发展有限公司  京ICP备09084417号