Comparison of flow cytometry with the Sysmex XT2000iV automated analyzer for the detection of reticulated platelets in dogs
Authors:Alexander Pankraz  Natali Bauer  Andreas Moritz
Institution:Department of Veterinary Clinical Sciences, Clinical Pathology and Clinical Pathophysiology, Justus‐Liebig University Giessen, Giessen, Germany
Abstract:Background: Immature (reticulated) platelets (r‐PLT) are not routinely assessed by hematology analyzers, but may be useful in the evaluation of the bone marrow response to thrombocytopenia. Objective: The aim of this study was to compare the Sysmex XT2000iV hematology analyzer with standard flow cytometry for the determination of r‐PLT percentage in dogs. Methods: Blood samples were obtained from 40 healthy dogs, 12 thrombocytopenic dogs, and 6 dogs with normal platelet counts but with disorders associated with increased thrombopoiesis. The percentage of r‐PLT was determined with a FACscan flow cytometer (r‐PLTF]) using CD61‐phycoerythrin antibody and thiazole orange, and with the PLT‐O channel of the Sysmex analyzer (r‐PLTS]). Mean platelet volume, platelet distribution width, and platelet large cell ratio were also determined on the Sysmex. Repeatability (intra‐assay precision) and effect of storage were tested for the automated analyzer. Results: The reference interval (mean±1.96 X SD) for r‐PLT(F) was 1.91±1.29% (range 0.78–3.68%) and for r‐PLT(S) was 0.56±0.82% (range 0.11–2.16%). For both flow cytometry and the Sysmex, the patient group had a significantly higher mean percentage of r‐PLT compared with the control group (P<.0001, unpaired Student's t‐tests). Fair correlation (r=0.71; Spearman's regression analysis) was found for r‐PLT results between the 2 methods, and a negative proportional systematic bias of ?6.26 was found for the Sysmex (Bland–Altman analysis). Based on receiver operating characteristic curves and a cut‐off of ≥0.975%, a sensitivity of 94.7% and a specificity of 85.7% were obtained for detecting r‐PLT on the Sysmex, using flow cytometry as the reference method. Blood samples stored at 4 °C and 25 °C had a significant increase in the percentage of r‐PLT after 24 and 48 hours, respectively. Conclusions: The PLT‐O channel of the Sysmex XT2000iV is capable of detecting immature platelets in healthy, thrombocytopenic, and nonthrombocytopenic ill dogs.
Keywords:Immune‐mediated thrombocytopenia  megakaryopoiesis  reticulated platelets  thrombopoiesis
设为首页 | 免责声明 | 关于勤云 | 加入收藏

Copyright©北京勤云科技发展有限公司  京ICP备09084417号