首页 | 本学科首页   官方微博 | 高级检索  
     


Limitations of acid digestion techniques for the determination of fluoride in plant material
Abstract:Abstract

Procedures for determination of fluoride (F) in plant material employing acid digestion and solution analysis by ion specific electrode (ISE) were compared to alkali fusion using a range of plant materials. The efficiency of the methods were assessed using standard reference plant material (SRM) not previously available for plant F analysis. All acid digestion procedures tested failed to obtain the certified value for F in the SRM. This was due to failure of the acids to liberate F bound strongly within silicate minerals found in the plant materials. Acid digestion is therefore not recommended for determination of total F, but could be used to determine labile F in plant materials. During investigation of the acid digestion procedures, it was also found that F concentrations determined in solution using the ISE are sensitive to solution pH, even at solution pH values where complexation of F with hydrogen ions (H+) can be discounted. It is therefore recommended that both ionic strength and pH of sample and standard solutions be matched when determining F concentrations in solution using the F‐ISE.
Keywords:
设为首页 | 免责声明 | 关于勤云 | 加入收藏