首页 | 本学科首页   官方微博 | 高级检索  
     


Testing and statistical analysis of the performance of a pipe drainage system: A case study in north-eastern Italy
Authors:Maurizio Borin  Antonio Berti
Affiliation:(1) Istituto di Agronomia Generale e Coltivazioni Erbace, Università di Padova, via Gradenigo 6, 35131 Padova, Italy;(2) Centro per lo Studio dei Diserbanti, CNR, via Gradenigo 6, 35131 Padova, Italy
Abstract:A survey program was carried out from June 1988 to august 1989 in North-eastern Italy in a pipe drainage area of 61 ha in order to verify if the year of installation (one part of the system has been installed in 1984 and another one year later) and the cover material of drains (pipes were covered with cocofibre for 2/5 of their length and without envelope for 3/5) could influence the functioning of the system. Collected data of drain discharge and water table depth were subjected to an elaborate statistical analysis.A methodological approach to determine the sample size (how many measurements of discharge and watertable depth are required, in space and time, from a statistical stand-point) in drainage experiment is proposed. For drainage systems similar to the considered one, a sample size of 10–12 drains and 6–8 observation wells can be recommended in order to obtain a standard error lower than 10–15% of the mean.
Keywords:drainage testing  pipe drainage  statistical analysis