首页 | 本学科首页   官方微博 | 高级检索  
     检索      


Serological responses of dogs to cell wall and internal antigens of Brucella canis (B. canis)
Authors:Steven J Zoha  Leland E Carmichael
Institution:James A. Baker Institute for Animal Health, New York State College of Veterinary Medicine, Cornell University, Ithaca, NY 14853 U.S.A.
Abstract:The serological responses of dogs to cell wall and internal antigens of B. canis were studied in experimentally infected specific-pathogen-free (SPF) Beagles. Sera from infected and false positive field dogs also were examined. Cell wall antigens were extracted from B. canis by two procedures that employed either hot phosphate buffered saline (PBS) or sodium desoxycholate (SDC). Agar gel immunodiffusion (AGID) tests employing sera from experimentally infected SPF dogs were used to evaluate antigenic extracts. Extraction with PBS yielded two antigens; SDC extracted an antigen complex and sonication of PBS extracted cells liberated four internal antigens.Sera from field dogs that were negative for B. canis infection in repeated tests often had heterospecific antibodies. Such cross-reactive sere commonly gave “spur” (partial fusion) reactions with a positive reference serum when tested against the SDC cell wall antigen. In addition, false positive dogs did not have antibody to one of the cell wall antigens or to the internal antigens. In contrast, sera from infected field dogs commonly gave “identity” (fusion) reactions in the AGID test with two antigens in the SDC extract, and produced precipitin lines to one to four internal antigens.Examination of a library of sera obtained from experimentally infected SPF dogs over a period spanning 412 years revealed that none of the serodiagnostic tests employed (tube agglutination, slide agglutination, AGID) was accurate during the inital 12 weeks of infection; hemocultures were the most sensitive during this period. Tube and slide agglutination tests were initially sensitive, but they showed a lack of sensitivity and specificity after the bacteremic period ceased, as well as in their failure to exclude false positive reactions in field animals. Immunodiffusion tests that employed SDC or PBS extracts of B. canis cell walls were sensitive and accurate in identifying most infected dogs. After the bacteremia had ceased, however, AGID tests that employed cell wall antigens gave equivocal results. Immunodiffusion tests that employed sonicated (internal) antigens were sensitive shortly after the onset of bacteremia, and they had the advantage of detecting infected animals for at least 6 months following the cessation of bacteremia, a time when other serological tests gave equivocal results.
Keywords:
本文献已被 ScienceDirect 等数据库收录!
设为首页 | 免责声明 | 关于勤云 | 加入收藏

Copyright©北京勤云科技发展有限公司  京ICP备09084417号