首页 | 本学科首页   官方微博 | 高级检索  
     

Research and Realization of Calculating Artery Compliance Using Oscillometric Method
引用本文:CHEN Yi-qing,HE Wei. Research and Realization of Calculating Artery Compliance Using Oscillometric Method[J]. 保鲜与加工, 2005, 0(9): 35-38
作者姓名:CHEN Yi-qing  HE Wei
摘    要:This paper presents a method that can non-invasively detect artery compliance using oscillometric method.There are also researches about Windkessel theory,and analysis of the combination of Windkessel and oscillometric method.Then the authors summarize a method to calculate artery compliance and introduce the clinical effect in the hospital.Compared with traditional sphygmomanometer,they get the pertinence of SBP is r=0.918 5(P<0.001).And the pertinence of DBP is r=0.899(P<0.001).Then it is compared with ultrasonic method,the pertinence of compliance is r=-0.820 9(P<0.01).This proves that the diagnose of blood pressure and artery compliance is effective and artery compliance is an important index in cardiovascular clinical measurement.So this paper makes the oscillometric method to be applied to wide ranges in calculating cardiovascular indexs.

关 键 词:,seillometrie method    compliance    cardiovascular diseases    windkessel
收稿时间:2005-05-13
修稿时间:2005-05-13

Research and Realization of Calculating Artery Compliance Using Oscillometric Method
CHEN Yi-qing,HE Wei. Research and Realization of Calculating Artery Compliance Using Oscillometric Method[J]. Storage & Process, 2005, 0(9): 35-38
Authors:CHEN Yi-qing  HE Wei
Abstract:This paper presents a method that can non-invasively detect artery compliance using oscillometric method.There are also researches about Windkessel theory,and analysis of the combination of Windkessel and oscillometric method.Then the authors summarize a method to calculate artery compliance and introduce the clinical effect in the hospital.Compared with traditional sphygmomanometer,they get the pertinence of SBP is r=0.918 5(P<0.001).And the pertinence of DBP is r=0.899(P<0.001).Then it is compared with ultrasonic method,the pertinence of compliance is r=-0.820 9(P<0.01).This proves that the diagnose of blood pressure and artery compliance is effective and artery compliance is an important index in cardiovascular clinical measurement.So this paper makes the oscillometric method to be applied to wide ranges in calculating cardiovascular indexs.
Keywords:,seillometrie method    compliance    cardiovascular diseases    windkessel
点击此处可从《保鲜与加工》浏览原始摘要信息
点击此处可从《保鲜与加工》下载全文
设为首页 | 免责声明 | 关于勤云 | 加入收藏

Copyright©北京勤云科技发展有限公司  京ICP备09084417号